To do...
Configure the source IP address
Configure the source port
Configure the number of probes
per test
Configure a test description
Configure the maximum number of
history records that can be saved
Enable history record
Configure the retaining time of
history record
Configure statistics interval and the
maximum number of retained
statistics information
Configure the retaining time of
statistics information
Configure test start time and
lifetime
Enable routing table bypass
Configure the TTL
Configure the automatic test
interval
Configure the probe timeout time
Configure the type of service
Use the command...
source-ip ip-address
source-port port-number
count times
description string
history-records number
history-record enable
history keep-time keep-time
statistics { interval interval |
max-group number }
statistics keep-time keep-time
test-time begin { hh:mm :ss
[ yyyy/mm/dd ] | now } lifetime
lifetime
sendpacket passroute
ttl number
frequency interval
timeout time
tos value
1-10
Remarks
Optional
By default, no source IP address is
configured.
Optional
By default, no source port is
configured.
Optional
By default, each test makes one
probe.
Optional
By default, no description information
is configured.
Optional
By default, the maximum number is
50.
Optional
By default, history record is not
enabled.
Optional
By default, the retaining time of
history record is 120 minutes.
Optional
By default, statistics interval is 120
minutes and up to two pieces of
statistics information can be retained.
Optional
By default, the retaining time of
statistics information is 120 minutes.
Optional
By default, no test start time and
lifetime is configured.
Optional
By default, routing table bypass is
disabled.
Optional
By default, TTL is 20.
The sendpacket passroute command
voids the ttl command.
Optional
By default, the automatic test interval
is zero seconds, indicating no
automatic test will be made.
Optional
By default, a probe times out in three
seconds.
Optional
By default, the service type is zero.