Toshiba e-studio200l Service Manual page 456

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

[E450]
LCF side cover opened during printing
Is the LCF side cover open?
YES Æ Remove the paper if there is any, then close the cover.
È
NO
Is the LCF side cover opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]OFF/[5]/[D])
NO Æ
l
l
l
l
l
l
l
l
l
l
l
l
È
YES
1) Replace the LCF board.
2) Replace the LGC board.
[E480]
Bridge unit opened during printing
Is the bridge unit open?
YES Æ Remove the paper if there is any, then close the unit.
È
NO
Is the bridge unit opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]ON/[3]/[F])
NO Æ
l
l
l
l
l
l
l
l
l
È
YES
Replace the LGC board.
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
1) Check if the connector of the LCF side cover opening/closing switch
is disconnected.
2) Check if either of the connectors CN100 or CN106 on the LCF board
is disconnected.
3) Check if the connector CN310 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the LCF board and LGC board are
short circuited or open circuited.
6) Replace the LCF side cover opening/closing switch.
7) Replace the LCF board.
8) Replace the LGC board.
1) Check if the connector of the bridge unit opening/closing switch is
disconnected.
2) Check if the connector CN306 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
5) Replace the bridge unit opening/closing switch.
6) Replace the LGC board.
5 - 26
June 2004 © TOSHIBA TEC

Hide quick links: