Duplex copying:
(1)
Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
(2)
If the image skew is "C" as shown in the figure below, shift the aligning plate in the direction of "-
", and if "D", shift it to "+".
Shift the aligning plate in the direction of "-".
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
Fig.3-100
Fig.3-99
C
Shift the aligning plate in the direction of "+".
3 - 78
05/11
Fig.3-101
June 2004 © TOSHIBA TEC
D