Toshiba e-studio200l Service Manual page 147

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Classifi-
Code
cation
518
Fuser
Fuser roller temperature
during printing
(Side thermistor/Thick
paper 3)
520
Fuser
Fuser roller temperature
during printing
(Center thermistor/Enve-
lope)
521
Fuser
Fuser roller temperature
during printing
(Side thermistor/Envelope)
523
Fuser
Pre-running time for first
printing
(Envelope)
525-0
Fuser
Temperature
drop switching
time setting
525-1
during printing
(Center ther-
525-2
mistor)
525-3
June 2004 © TOSHIBA TEC
Setting mode (08) <e-STUDIO200L/230/280>
Default
Func-
<Accept-
Items
tion
value>
ALL
<0-14>
ALL
<0-14>
ALL
<0-14>
ALL
<0-15>
The first
ALL
drop
<0-200>
The sec-
ALL
ond drop
<0-200>
The third
ALL
drop
<0-200>
The fourth
ALL
drop
<0-200>
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 111
05/05
RAM
Contents
able
9
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
9
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
9
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
10
M
0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
20
M
This code is valid only
when "20" is set to 08-
535.
38
M
Setting value x 5 sec.:
from 0 to 1,000 sec.
75
M
later
75
M
Proce-
dure
1
2
1
1
1
4
4
4
4

Hide quick links:

Advertisement

Table of Contents
loading