Toshiba e-studio200l Service Manual page 227

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Classifi-
Code
cation
680
General
Banner advertising display
2
681
General
Display of [BANNER MES-
SAGE] button
682
User
Offsetting between jobs
interface
683
General
Duplex printing setting
when coin controller is
used
684
General
Rebuilding all databases
685
General
Rebuilding all databases
related to address book
686
General
Rebuilding all databases
related to log
689
FAX
Adaptation of paper source
priority selection
690
General
HDD formatting
691
General
HDD type display
692
Mainte-
Performing panel calibra-
nance
tion
693
General
Initialization of NIC infor-
mation
694
General
Performing HDD testing
June 2004 © TOSHIBA TEC
Setting mode (08) <e-STUDIO202L/232/282>
Default
Func-
<Accept-
Items
tion
value>
ALL
ALL
ALL
ALL
ALL
ALL
ALL
FAX
ALL
ALL
ALL
ALL
ALL
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 191
05/11
RAM
Contents
able
-
SYS
Maximum 27 letters
(one-byte character)
0
SYS
0: Not displayed
<0-1>
1: Displayed
*
This button enables
the entry of "Banner
advertising display 1
(08-679)" and "Ban-
ner advertising dis-
play 2 (08-680)" on
the control panel.
1
SYS
0: Invalid
<0-1>
1: Valid
1
SYS
When the duplex print-
<0-1>
ing is short paid with a
coin controller, reverse
side of the original is
not printed and is con-
sidered as a defect
(printing job may be
cleared). To solve this
problem, the selection
of printing method is
enabled with this set-
ting.
0: Invalid (Both sides
printed)
1: Valid (Only one side
printed)
-
SYS
Rebuilds all databases.
-
SYS
Rebuilds all databases
related to the Address
Book.
-
SYS
Rebuilds all databases
related to the log.
0
SYS
0: Not subjected for
<0-1>
APS judgment
1: Subjected for APS
judgment
-
SYS
2: Normal formatting
<2>
-
SYS
0: Not formatted
<0-2>
1: Not used
2: Normal format
-
SYS
Performs the calibration
of the pressing position
on the touch panel
(LCD screen). The cali-
bration is performed by
pressing 2 reference
positions after this code
is started up.
-
SYS
Returns the value to the
factory shipping default
value.
-
SYS
Checks the bad sector.
Proce-
dure
11
1
2
1
1
3
3
3
1
7
7
1