Toshiba e-studio200l Service Manual page 210

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Classifi-
Code
cation
404-0
Fuser
Temperature
drop setting in
ready status
404-1
(Center ther-
mistor)
404-2
404-3
405-0
Fuser
Temperature
drop setting in
ready status
405-1
(Side ther-
mistor)
405-2
405-3
407
Fuser
Fuser roller temperature in
ready status
(Side thermistor)
409
Fuser
Fuser roller temperature at
energy saver mode
(Center thermistor)
410
Fuser
Fuser roller temperature
during printing
(Center thermistor/Plain
paper)
411
Fuser
Fuser roller temperature on
standby
(Center thermistor)
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08) <e-STUDIO202L/232/282>
Func-
Items
tion
The first
ALL
drop
The sec-
ALL
ond drop
The third
ALL
drop
The fourth
ALL
drop
The first
ALL
drop
The sec-
ALL
ond drop
The third
ALL
drop
The fourth
ALL
drop
ALL
ALL
ALL
ALL
2 - 174
05/11
Default
<Accept-
RAM
able
value>
1
M
This code is valid only
<0-10>
when "20" is set to 08-
886.
1
M
Setting value x -5°C:
<0-10>
from 0°C to -50°C
1
M
<0-10>
1
M
<0-10>
4
M
<0-10>
4
M
<0-10>
4
M
<0-10>
4
M
<0-10>
8
M
0: 140°C 1: 145°C
<0-12>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
0
M
0: OFF
<0-13>
2: 50°C
4: 70°C
6: 90°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
8
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
8
M
0: 140°C 1: 145°C
<0-12>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
Proce-
Contents
dure
4
4
4
4
4
4
4
4
1
1: 40°C
1
3: 60°C
5: 80°C
7: 100°C
1
1
June 2004 © TOSHIBA TEC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents