(4)
Fix the plate spring temporarily with the
screw on the left. Then press the plate spring
Plunger
slightly in the direction of an arrow and
tighten the screw in the position where the
D
D
gap (D) between the plunger and the flapper
lever is eliminated.
Flapper lever
3
Fig.3-74
June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 65