[B]
Adjustment of the magnification ratio of the lens
Notes:
Perform this adjustment only when the lens unit is taken off or replaced.
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1)
Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(2)
Compare the copied ruler with the actual
ruler.
(3)
If each mark on the rulers differs, perform the adjustment with the following procedures.
<Procedure>
(1)
Take off the original glass and lens cover.
(2)
Loosen 2 screws fixing the lens unit.
June 2004 © TOSHIBA TEC
Feeding Direction
Copied ruler
Fig.3-37
Screw
Fig.3-38
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 47
Actual ruler
Lens unit