Toshiba e-studio200l Service Manual page 344

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

(3)
Slide the lens unit to the right or left direction using the marks on the lens base as a guide. (Slide
right when the copied ruler is magnified and slide left when the copied ruler is demagnified.)
The following table shows how the reproduction ratio difference between the copied ruler and
actual ruler corresponds to the movement amount of the lens unit.
Reproduction-ratio error
Note:
Note:
Fine adjustment can be made in the "Reproduction ratio of primary scanning direction (printer)".
on the copied ruler and actual ruler match.
(4)
Tighten 2 screws fixing the lens unit.
(5)
Attach the lens cover and original glass. Make a copy to confirm the reproduction ratio.
(6)
Repeat the procedure 1 to 5 until the marks on the copied ruler and actual ruler match.
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
0.1%
0.2%
0.3%
0.4%
0.5%
0.6%
0.7%
0.8%
0.9%
1.0%
Movement amount of unit
Lens unit
Fig.3-39
3 - 48
0.5 mm
0.9 mm
1.4 mm
1.8 mm
2.3 mm
2.7 mm
3.2 mm
3.6 mm
4.1 mm
4.5 mm
June 2004 © TOSHIBA TEC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents