[B]
Reproduction ratio adjustment of the primary scanning direction
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON Æ (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
*Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(5)
Check if the distance A is within the range of 260±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) Æ (Key in the code [405]) Æ [START]
Æ (Key in a value (acceptable values: 0 to 255))
Æ Press the [ENTER] or the [INTERRUPT] button (stored in memory).
Æ ("100% A" is displayed.)
*The larger the adjustment value is, the higher the reproduction ratio and the longer the distance
A become (approx. 0.125 mm/step).
Copied image of the ruler
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
Feeding direction
Fig.3-12
3 - 14
04/09
June 2004 © TOSHIBA TEC