Toshiba e-studio200l Service Manual page 139

Multifunctional digital systems
Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Classifi-
Code
cation
409
Fuser
Fuser roller temperature at
energy saver mode
(Center thermistor)
410
Fuser
Fuser roller temperature
during printing
(Center thermistor/Plain
paper)
411
Fuser
Fuser roller temperature on
standby
(Center thermistor)
412
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 3)
413
Fuser
Fuser roller temperature
during printing
(Center thermistor/Thick
paper 1)
June 2004 © TOSHIBA TEC
Setting mode (08) <e-STUDIO200L/230/280>
Default
Func-
<Accept-
Items
tion
value>
ALL
<0-13>
ALL
<0-14>
ALL
<0-12>
ALL
<0-14>
ALL
<0-14>
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 103
04/09
RAM
Contents
able
0
M
0: OFF
1: 40°C
2: 50°C
3: 60°C
4: 70°C
5: 80°C
6: 90°C
7: 100°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
8
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
8
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
9
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
8
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
Proce-
dure
1
2
1
1
1
1

Hide quick links: