6. Other
6.3.22

CCD Unit

A. Replacing Procedure
1. Remove the IR Upper Left Cover.
See P.48
2. Remove the Front Holding Bracket.
See P.48
3. Remove the Original Glass.
See P.48
[2]
[1]
[4]
[3]
[7]
B. Installation Adjustment to be Made when CCD Unit is Replaced
NOTE
• Make this adjustment only when the CCD Unit has been replaced with a new one.
• Before attempting to make this adjustment, make sure that registration and erase
adjustments for the printer have been completed.
• Do not loosen or remove the screws shown below.
64
[1]
[1]
4040F2C675DA
[5]
[6]
4040F2C676DA
Confidential – for internal use only, do not distribute
Field Service Ver. 2.5 Jul. 2006
4. Remove six screws [1] and the CCD
Unit Cover [2].
5. Move the Exposure Unit, remove the
wiring saddle [3], and disconnect the
connector [4].
6. Remove two screws [5] and two flat
springs [6]. Then, remove the CCD
Unit [7].
NOTE
When the CCD Unit has been replaced
with a new one, make the installation
adjustment that must be made when
the CCD Unit is replaced.
See P.64
4030D601AA