Configuring the CBR
Module
To configure the Ethernet 10/100 interface:
1 From the Configuration Management menu, select [1] Manage Card.
2 From the list Card menu, shown earlier in Figure 60, enter the number
corresponding to the slot in which the Ethernet 10/100 module is installed (
to open the PCI Ethernet Configuration menu, shown in Figure 108.
Figure 108 PCI Ethernet Configuration Menu
3 Set the following parameters:
Admin. Status — The administrative status of the PCI Ethernet interface: In
Service or Out of Service.
Media Type — The port speed: 10Mpbs half duplex, 100 Mbps half duplex,
10Mbps full duplex, 100 Mbps half duplex, or autosensing. The actual line speed
(Operational Media Type) is displayed under Oper Media Type in the information at
the top of the PCI Ethernet Configuration menu.
If you set the Media Type to autosensing, the port automatically detects the port
speed and duplex mode and sets itself accordingly. If the equipment to which the
PathBuilder S330/S310 switch is connected does not support autosensing, the
port falls back to the speed of the remote equipment.
The optional CBR module features three T1/E1 CBR ports and one serial port
(PathBuilder S330 switch) or one T1/E1 CBR port and one serial port
(PathBuilder S310 switch).
Configuring the CBR module involves the following tasks:
Configuring the CBR T1/E1 port(s)
Configuring the CBR serial port
Configuring the CBR card
Configuring the CBR Module
115