Figure 5–1 Power Supply Locations - Base and DEM (Rear View)
Figure Legend:
Robotics DC power supplies (1200W DC)
1.
Electronics module DC power supplies (200W cPCI)
2.
Tape drive DC power supplies (1200W DC)
3.
Power distribution unit (120 VAC or 240 VAC)
4.
Electronic Control Module Power Supplies
The electronics control module (ECM) uses 200 W cPCI power supplies. These power
supplies are located below the HBT card in the Base module (there are no ECM power
supplies in the DEM) — see
module is different from the power supplies used for the robotics unit and the tape
drives.
Each Base module ships standard with two ECM power supplies used for N+1 and 2N
configurations. Order two additional ECM supplies for the 2N+1 configuration (see
"DC Power Supplies"
Robotics Unit Power Supplies
The robotics unit uses load sharing 1200 W DC power supplies located at the top of the
Base module (the DEM does not contain robotics DC supplies) — see
1200 W DC power supply used for the robotics unit is the same power supply used for
the tape drives.
Each Base module ships standard with two robotics DC power supplies used for N+1
and 2N configurations. Order a third DC power supply for the 2N+1 configuration
(see
"DC Power Supplies"
Figure
5–1. The power supply for the electronics control
on page 9-9).
on page 9-9).
DC Power Supplies
Figure
5–1. The
Power and Cooling 5-3