Dc Power Supplies; Power Supply Locations - Base And Dem (Rear View) - Oracle StorageTek SL3000 Manual

Modular library system
Hide thumbs Also See for StorageTek SL3000:
Table of Contents

Advertisement

Power Configurations
Required for redundant robotics and redundant electronics support
2N+1 power configuration
Offers both AC and DC power redundancy with additional DC redundancy
Consists of two PDUs (per Base module or DEM) for AC redundancy, with
additional DC power supplies for each PDU
Provides N+1 DC power redundancy for each PDU (except the second PDU only
has N DC power supply redundancy for the robot)
Requires two separate AC input sources per Base module or DEM
Supports redundant robotics and redundant electronics

DC Power Supplies

There are two types of DC power supplies:
Load sharing 1200W DC — used for the robotics unit and tape drives
200W cPCI — used for the electronics control module
Figure 1–7 Power Supply Locations - Base and DEM (Rear View)
Figure Legend:
Robotics DC power supplies (1200W DC)
1.
Electronics module DC power supplies (200W cPCI)
2.
Tape drive DC power supplies (1200W DC)
3.
Power distribution unit (120 VAC or 240 VAC)
4.
1-10 StorageTek SL3000 Library Guide