NX-10 technical specifications

Mains input voltage, small housing
Mains input voltage, large housing
Current, typical system, 25 VA transformer
Current, typical system, 40 VA transformer
Board input voltage
Output voltage
Maximum total current, 25 VA (40 VA)
Maximum auxiliary output current (AUX PWR+)
Maximum expansion bus output current (POS (+))
Typical main board current consumption
Battery type and maximum capacity, small housing
Battery type and maximum capacity, large housing
EN/INCERT battery charge time, 7.2 Ah (14.4 Ah)
EN/INCERT battery stand-by time, 7.2 Ah (14.4 Ah)
Available access code sizes
End of line resistor
Built-in Siren Driver
Number of relay outputs, and NC/NO rating
Indoor siren (wired) output rating
Environmental
Mains fuse, 25 VA (40 VA)
Mains power specifications
230 V ~ (+10% / - 15%) / 50 Hz / 25 VA
230 V ~ (+10% / - 15%) / 50 Hz / 40 VA
0.12 A ~ / 50 Hz / 25 VA
0.20 A ~ / 50 Hz / 40 VA
16.5 V ~ / 50 Hz
Power supply specifications
13.8 V
1.4 A
1.0 A
1.0 A
90 mA
Lead/Acid, 12 V nominal, 7.2 Ah
Lead/Acid, 12 V nominal, 2 x 7.2 Ah = 14.4 Ah
72 hours, at 200 mA (400 mA) charge current
12 hours, at 550 mA (1.1 A) total system load
General feature specifications
4 digits or 6 digits
3.3 KOhm, 2% 0.25 W
2 tone (Temporal and Yelp)
2 relays, 1/1 A at 13.8 V
1 A at 13.8 V
± 10%
Operating
temperature
Humidity
Shipping Weight
Fuses
315 mA (630 mA) T 250V 20x5
NX-10 Installers manual
± 2%
(2.0 A =) ± 5%
± 5%, fused, auto-restoring
± 5%, fused, auto-restoring
± 5%, EOL resistors applied
± 10%
-10° C to +55 °C
Max 95% non condensing
1.7 kg