Connecting the NX-586E to a panel

Connect the cable with alligator clips to a NX-10 panel as follows:
Red to POS
Black to COM
Green to DATA

Programming the NX-586E direct connect module

Figure 29. NX-586E menu structure
Files
13.1
13.1.
Options
13.2
13.2.1
The control panel's programming memory can be copied to one of the four programming memories
in the NX-586E direct connect module and vice-versa. You must enrol and default the module before
you begin to program the system. For more information on enrolling and defaulting, see Chapter B7
Enrolling modules.
To program the NX-586E using the NX-1048 keypad, select Installer Menu>NX-586E Direct
Connect Module. To program the NX-586E using a PC, start the DL900 up/download software on
the PC.
Note: It is recommended to up/download data when the keypad is in the operating mode only (not in the
programming mode). If you are in the Installer Menu the keypad can time out and start copying process
which will interfere with or stop up/downloading in progress.

Enabling memory transfer using the keypad

The following example uses the NX-1048 keypad to copy the control panel's programming memory
to the NX-586E programming memory 2. It then copies programming information from the NX-
586E programming memory 3 to the control panel.
Navigate with the
1.
To write information from the control panel to the NX-586E, scroll to File 2>Panel to
2.
File and press OK.
Select Yes to confirm and press OK.
3.
The control panel's programming memory is copied to the NX-586E direct connect
4.
module's programming memory 2. The Receiving Data LED on the NX-586E direct
connect module flashes while the data is received. The keypad sounder chimes when the
operation is successful.
To read information from the NX-586E to the control panel, scroll to File 3>File to
5.
Panel and press OK.
Select Yes to confirm and press OK.
6.
The information in the NX-586E programming memory 3 is copied to the current control
7.
panel. The Sending Data LED on the NX-586E direct connect module flashes while the
data is received. The keypad sounder chimes when the operation is successful.
File 1
13.1.1.
Files 2 - 4
13.1.1.2
Same as above
13.1.1.3
Speed
keys to NX-586E Direct Connect Module>Files and press OK.
Panel Type
Panel to File
File to Panel
NX-10 Installers manual