GE NX-10 Installer Manual page 65

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Location
Term
2.1.3.1.1.2
24-hour
2.1.3.1.1.3
Keyswitch
2.1.3.1.1.4
Delay 1
2.1.3.1.1.5
Delay 2
2.1.3.1.1.6
Interior
2.1.3.1.1.7
Entry Guard
2.1.3.1.1.8
Cross Zone
2.1.3.1.1.9
Trouble
2.1.3.1.1.10
Follower/Access
2.1.3.1.2
Zone Type Name
2.1.3.1.3
Attributes
2.1.3.1.3.1
End of Line Resistor
2.1.3.1.3.2
Defeat EOL Resistor
2.1.3.1.3.3
Loop Response
Definition
A zone type where reaction is not dependent on the
arm/disarm state of the system. It is permanently active 24
hours a day unless bypassed by forced arming. An
example of a 24-hour zone is a fire, panic or glassbreak
zone.
A zone type that can be used to arm or disarm a partition
using a switch connected to a zone instead of a code. Both
pulsed and maintained keyswitches can be used.
A zone type whose events can be delayed for a specified
interval before a zone creates an alarm. This type of zone is
usually used to allow exit and entry to a building. The time
intervals for a Delay 1 zone are defined in Entry 1 and Exit
1.
A zone type whose events can be delayed for a specified
interval before a zone creates an alarm. This type of zone is
usually used to allow exit and entry to a building. The time
intervals for a Delay 2 zone are defined in Entry 2 and Exit
2.
A zone type that is automatically bypassed when the
system is armed in stay mode.
A zone type that reduces false alarms. If an armed entry
guard zone is opened, the keypad sounder activates and
the entry delay starts before creating an alarm. This can be
programmed as a zone type.
A zone type that requires two or more trips within a
specified time before it will report an alarm.
A zone type that sends an alarm when the system is armed
and trouble when the system is disarmed.
A zone type that follows a state of the entry/exit zone.
Usually it is a delayed zone when the system is open, and
an instant burglary zone during non-entry times This option
allows to toggle the follower setting. This option is visible
only if the 24-hour input type option is disabled.
A menu option that specifies the name of a particular zone
type. This option also allows the name to be edited.
A menu entry that groups the additional characteristics of
the selected zone type.
A zone characteristic that specifies that two 3k3 end of line
resistors are used.
An end of line resistor (EOL) is a resistor that is placed on
the line to stop the signal being bounced back.
A menu option that disables the end of line resistor of the
specified zone type.
A zone characteristic of on-board control panel zones that
specifies the response rate. This can be either 500 ms or 50
ms.
NX-10 Installers manual
65