Specifications

78
Option 91 Comm Channel 2 Reports
The setting for this option determines which reports are sent to central station receiver 2
by the Ethernet Interface module.
Option 92 Comm Channel 3 Reports
The setting for this option determines which reports are sent to the premisescon-
nect.com website by the Ethernet Interface module.
Option 93 DTIM Reports Phone 1
The setting for this option determines what events the DTIM reports on phone 1.
Option 94 DTIM Reports Phone 2
The setting for this option determines what events the DTIM reports on phone 2.
Option 96 HWIN2 Output Function
The setting for this option determines how the HWIN2 output will function.
Option 97 HWIN1 Output Function
The setting for this option determines how the HWIN1 output will function.
Power Requirements: .....9 VAC, 700 mA
Rechargeable Batteries: ..6.0 VDC, 1.2 Ah Lead-Acid. The battery will last 24 hours with no
AC and specified standby load
Radio Frequency: ............319.5 MHz (60-875) 433 MHz (60-910)
Nominal Range: ..............500 feet (152 meters), open-air receiving range
Storage Temperature Range:-29° to140° F (-34° to 60° C)
Operating Temperature Range: 32° to 120° F (0° to 49° C)
Maximum Humidity: ......90% relative humidity, noncondensing
Auxiliary Power: .............Unregulated 5.1 - 12 VDC, power-limited to 250 mA (maximum) @
10 VDC
Simon Security System