GE NX-10 Installer Manual page 178

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

zones for all these events), and Code Entry (it filters out users). For all other events this setting is
ignored.
Segment 3 - Time
Selects the amount of time an output will remain activated when an output triggers. If this location is
programmed as a zero, the output will follow the particular event.
LOCATION 71 - PROGRAMMING SPECIAL FUNCTIONS AND PARTITIONS FOR OUTPUT 1 (2
segments, feature selection data)
Segment 1 - selects the following special conditions
Option
Function
1
ON
If output should time in minutes
OFF
If output times in seconds
2
ON
Output "Latch": should latch until a code is entered
OFF
Output is timed
3
ON
Timed or output should be reset if a code is entered while it is being timed
OFF
Stays timed (not reset) after code is entered
8
Reserved
Segment 2 - selects the following partitions
Option
Function
1
ON
If the event should activate when it occurs in partition 1
2
ON
If the event should activate when it occurs in partition 2
3
ON
If the event should activate when it occurs in partition 3
4
ON
If the event should activate when it occurs in partition 4
LOCATION 72 - PROGRAMMING THE X-10 LOCATION FOR OUTPUT 1 (2 segments, numerical
data)
Segment 1 - Unit code
Program a number from 0-15 to represent the corresponding X-10 unit code from the following table.
Module
1
2
Segm 1
0
1
3
4
5
6
2
3
4
5
7
8
9
10
6
7
8
9
11
12
13
14
10
11
12
13
15
16
14
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents