A canned CO testing agent must be used for the CO functional gas
test.
1.
Wait at least 10 minutes after installation to test the CO
alarm.
2.
Make sure the green Power LED is flashing for normal
operation.
3.
Set the control panel to sensor test mode.
4.
Press and hold the Test/Hush button until the unit beeps
three times (approximately 10 seconds), and then release the
button. The unit will enter the functional gas test mode. The
Power LED will blink once per second while in functional test
mode.
5.
Apply UL approved CO test agent. When CO is detected, the
unit will activate a CO alarm. The unit will send RF test
packets to the control panel when the CO alarm is activated.
6.
The control panel will beep and display the number of RF
packets received.
7.
At the control panel, exit sensor test mode.
8.
Exit functional gas test mode:
Press and release the Test/Hush button; or
A 2 minute timeout will automatically cause the CO to return
to normal operating mode.

Troubleshooting

This information is provided to help you diagnose and solve
various problems that may arise while configuring or using the
wireless CO alarm.
Unit does not power up properly or reports low battery:
Make sure the batteries are fully seated within the battery
compartment and the polarity is correct.
Make sure that all three batteries are installed.
Check the battery voltage (1.5 VDC nominal per battery).
Control panel does not respond:
Use the 60-401 RF Sniffer to make sure the CO alarm is
sending messages for activation.
Move or rotate the CO alarm position.
Make sure the CO alarm is properly enrolled into the control
panel.
Make sure that you are using a compatible control panel (see
"Specifications" below).
Tamper condition does not restore:
Make sure the CO alarm body is properly installed on the
mounting plate.
Make sure there are no trouble indications at the CO alarm.
Make sure that you are using a compatible control panel (see
"Specifications" below).
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
In accordance with FCC requirements of human exposure to radio
frequency fields, the radiating element shall be installed such that a
minimum separation distance of 20 cm is maintained from the general
population.
4 / 8
If a tamper alarm occurs:
Make sure that you are using a compatible control panel (see
"Specifications" below).
Make sure that the control panel is in sensor test mode
during sensor testing.
Alarm/open condition does not restore:
Make sure that the CO alarm condition has cleared at the CO
alarm.
Make sure that you are using a compatible control panel (see
"Specifications" below).

Specifications

Compatible panels
Simon XT (firmware 1.4 or greater)
Power
Three AA batteries
Battery type
1.5 VDC alkaline
Required batteries
Duracell MN 1500, Duracell MX1500, Energizer
E91
Sensor
Electrochemical
Sensor life
7 years
Frequency
319.5 MHz
Supervisory interval
64 minutes
Audible alarm
Temporal 4
Alarm response times
70 PPM = 60-240 min.
150 PPM = 10-50 min.
400 PPM = 4-15 min.
Dimensions
4.68 x 2.75 x 1.85 in. (119 x 70 x 47 mm)
Storage temperature
-4 to 140°F (-20 to 60°C)
Operating environment
Temperature
40 to 100°F (4.4 to 37.8°C)
Relative humidity
10 to 95% noncondensing

Regulatory information

ETL rating
ANSI/UL 2034
FCC compliance
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
FCC ID: B4Z-929A-CO
IC: 1175C-929ACO
This Class B digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
P/N 466-2393 • REV 00.15 • ISS 07DEC10