GE NX-10 Installer Manual page 66

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Location
Term
2.1.3.1.3.4
Swinger Zone
2.1.3.1.3.5
Bypassable
2.1.3.1.3.6
Force Armable
2.1.3.1.3.7
Group Bypass
2.1.3.1.3.8
Zone Activity Monitor
2.1.3.1.3.9
Access Control
2.1.3.1.3.10
Pulsed Keyswitch
2.1.3.1.3.11
Req. To Exit
2.1.3.1.4
Sound
2.1.3.1.4.1
Yelping Siren (Burglary)
2.1.3.1.4.2
Steady Siren (Fire)
2.1.3.1.4.3
Audible Keypad
2.1.3.1.4.4
Chime
2.1.3.1.5
Reporting
2.1.3.1.5.1
Local Only
2.1.3.1.5.2
Restore Reporting
Definition
A zone characteristic that allows the selected zone to be
automatically bypassed after a specified number of
alarms.
A zone characteristic that allows the zone to be bypassed.
A zone characteristic that allows the zone to be force
armed.
A zone characteristic that allows the user to bypass
multiple zones with a single operation.
A zone characteristic that sends a report to the central
station when the zone does not change conditions within a
specified time period.
A zone characteristic that enables the zone to act as an
access entry point (door shunt). Do not enable this setting
unless the system is configured with a door control.
A zone characteristic that allows a zone input to be used
with a momentary keyswitch. Each activation of the
keyswitch toggles the armed state of the control. This
option is visible only if the Keyswitch input type option is
enabled.
A zone characteristic that enables the zone to act as a
request to exit input.
A menu entry that groups sounder characteristics for a
particular zone type. These characteristics determine the
sounds produced by the sirens and keypads when the
selected zone is activated.
A menu option that sounds a burglary siren when a zone is
activated.
A menu option that sets whether a zone type activates a
fire or a burglary siren.
A menu option that activates the keypad buzzer when an
alarm occurs.
A menu option that sets whether a zone type activates a
chime.
A chime is generally a single stroke signal and is often used
as an indication on a shop door. This can be set as a zone
type. There is a beep on chime activation and no beep on
deactivation.
A menu entry that groups reporting options for the
selected zone type.
A zone characteristic that causes that zone not to report
alarms to the central station. Locally, the sirens are
activated according to the other zone type characteristics.
This option is visible only if the Keyswitch input type option
is disabled.
A menu option that causes restore events to be reported to
the central station.