Networx V3 Technical Specifications - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

NetworX V3 technical specifications

Table 1.
Available NetworX V3 panel models
Panel models
NX-5
NX-7
NX-9, NX-11
NX-10
Table 2.
NetworX V3 technical specifications
Mains power specifications
Mains input voltage
Current consumption at 230 VAC
Main board supply voltage (AC: CON8)
Power supply specifications
Power supply type
Power supply voltage [5]
Power supply current
Main board consumption:
Non-GSM variant
GSM variant
Maximum system current available [1]
Non-GSM variant
GSM variant
Auxiliary power output (AUX PWR+,
POS) [2]
Battery type
Maximum voltage at power supply,
auxiliary power output and battery
power output
Battery low condition
Deep discharge protection [7]
Maximum ripple voltage Vpp [3]
Onboard zones capacity
NX-xx(-GSM)-EUR
230 VAC +10%, −15%, 50Hz
±10%, 25 VA
120 mA typical, 300mA max.
NX-xx(-GSM)-EUR
Type A, EN 50131-6
Min. 9.5 V
Typ. 13.8 V
Max. 14.4
0.9 A max. at 13.8 V
± 2%
145 mA ± 10% at 13.8 V
180 mA ± 10% at 13.8 V
740 mA max. at 13.8 V
± 2%
700 mA max. at 13.8 V
± 2%
See Table 2
Lead acid rechargeable,
7.2 Ah 12 V nom. (BS127N)
300 mV typical, 600 mV max.
NetworX Version 3 Installation Manual
0
6
8
2
NX-xx(-GSM)-LB-EUR
230 VAC +10%, −15%, 50Hz ±10%,
40 VA
200 mA typical, 500mA max.
16.5 VAC typical
NX-xx(-GSM)-LB-EUR
± 2%
± 2%
± 2%
1.8 A max. at 13.8 V
± 2%
± 2%
1640 mA max. at 13.8 V
1600 mA max. at 13.8 V
See Table 3
Lead acid rechargeable,
7.2 Ah 12 V nom. (BS127N) or 12 Ah
12 V nom. (BS130N)
14.4 V
11.6 V
9.7 V
13
± 2%
± 2%
± 2%