user code. Disarming the system clears the bypassed zone set.
Group Bypass
Automatically bypasses all the zones with the Group Bypass attribute set (for example,
Interior Follower with Group Bypass Enabled zone type). It is a shortcut for the User
Menu>Group Bypass menu option. To cancel Group Bypass function press the button again.
To partially arm the system with the selected zones bypassed, enter the user code.
Disarming the system clears the bypassed zone set.
Allows to turn on or off the X-10 devices connected to the system. It is a shortcut for the
Light Control
User Menu>Light Control menu option.
Alarm Memory
Displays the alarm memory list. It is a shortcut for the User Menu>Alarm Memory menu
option.
Service Check
Performs the service check. It is a shortcut for the User Menu>Service Check menu option.
Detector Reset
Resets all the detectors. It is a shortcut for the User Menu>Detector Reset menu option.
Answers an upload/download call. It is a shortcut for the User Menu>Download>Answer U/D
Answer U/D Call
Call menu option.
Begin U/D Call
Starts an upload/download call. It is a shortcut for the User Menu>Download>Begin U/D Call
menu option.
Silent Exit
Prevents the exit time buzzer activating when the system is armed or during the re-exit
time. It is a shortcut for the User Menu>Silent Exit menu option. This function also doubles
the exit delay (for example, if exit delay is set to 30 seconds, it changes to 60 seconds).
Chime
Toggles the Chime mode off and on (there is a chime icon displayed to indicate the mode
selected) for the Chime type zones. A chime is often used as an indication on a shop door.
There is a beep on chime activation and no beep on deactivation.
Panic Keypad
Starts the panic alarm, which can be cancelled by entering the user code. Depending on the
partition settings, the panic alarm can be silent or audible (see Emergency Keys, Silent PA,
Audible PA, Speaker Lockout menu option descriptions in the glossaries). The alarm is
reported and is listed in the event log.
Note: When you press the panic key and This keypad>Keypad Features>Beep on Panics
option is disabled, no keystroke sound is emitted.
Medical (Aux2)
Starts the medical alarm, which can be cancelled by entering the user code. The alarm is
reported and is listed in the event log. For the function to work, the Medical/Aux 2 menu
option must be set for the partition. Depending on the Emergency Keys menu option setting,
this alarm can be silent or audible.
Starts the fire alarm, which is always audible. The alarm is reported and is listed in the event
Fire Alarm
log. For the function to work, the Fire/Aux 2 menu option must be set for the partition.
Phone Number
Allows the user to enter up to three telephone numbers to which events are reported by the
control panel. It is a shortcut for the User Menu>Phone Numbers menu option. For the
function to work, the User Phone Editing menu option must be enabled, and the voice
protocol must be set for reporting. Voice protocols typically report to the homeowner's
mobile phone rather than to the central station.
The Phone No. prompt displays. Type the telephone ID (1 to 3) and press OK. The Enter Phone
No. prompt displays. Type the telephone number the way it should be dialled by the
communicator (including the all necessary prefixes) and press OK.
Arm Night Mode
Arms the system in Night mode. Arming with the function key will report as User 98.
Note: This shortcut works only if the Quick Arm menu option was set. For this mode to work
correctly, entry guard zones must be set. It works differently in the master mode and in the
single-partition mode. For more information on this button behavior, see the Master Keypad,
and the Quick Arm menu option description in the glossary.
Cancel
Pressing the Cancel button stops sending reports to the central station.
Info Key
This function displays the Custom Message on the LCD screen. Displaying is finished after
OK or No key is pressed.

Setting up the tamper switch

The wireless keypad has a pry-off switch. The installer decides how the keypad behaves whenever
NX-10 Installers manual