Term
Option 3
Output Latched
Outputs
Partitions
Partitions
Receiver Features
Reset Settings
RF Keypads
RF Receiver 32
RF Sensors
RF Sirens/IO
RSSI RF Device
Sequential Programming
Short Window
Sirens/IO Features
Definition
keyfob function 2 (see below).
A menu option used for configuring a sensor. For actual setting description, see
the particular sensor manual.
A menu option that specifies the way the output is timed. If set to Yes, the
output will latch until a code is entered. When set to No, the output is timed
according to Time setting.
Note: Do not set up this option for system status events (such as "Ready to
Arm", "Not Ready to Arm", "Armed", "Disarmed") because once the output is
triggered it will not reset to reflect current status unless the user code is
entered.
A menu entry that groups programmable options for IO modules.
A menu entry that lists the partitions assigned to the selected keyfob. The
selected keyfob can trigger an event on these partitions.
A zone may reside in any combination of partitions. A zone that resides in more
than one partition becomes a common zone and is reported to its lowest
partition number. A common zone is armed only when all the partitions that it
belongs to are armed. It is disarmed the moment one of the partitions it
belongs to is disarmed.
Selects the partition(s) that will trigger the output when the event occurs in
these partition(s).
A menu entry that groups programmable options for RF receivers.
A menu option that defaults the selected receiver to factory defaults.
A menu entry that displays the RSSI value for the selected wireless keypad.
A menu entry that groups all options for the selected RF receiver. The
integrated NX-10 RF receiver has ID 32.
A menu entry that displays the RSSI value for the selected wireless zone.
A menu entry that displays the RSSI value for the selected wireless siren or IO
module.
A menu entry that groups entries related to measuring RF signal strengths.
A menu option that allows a group of RF sensors to be enrolled in sequence.
Once the first sensor (Start Learning sensor) is configured, the detectors are
learned-in in sequence. The value of 'Start Learning' is increased automatically.
This option allows easier programming.
A menu option that specifies the short supervision window for RF devices. RF
devices on 868 MHz typically report every 15 minutes. Depending on the
country regulations, this timer must be set to specific values.
A menu entry that groups troubleshooting options for IO modules.