GE NX-10 Installer Manual page 206

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Term
Definition
Auto-answer
An Up/download setting that configures the NX-7002 to automatically answer any incoming calls. To
enable this setting, you must enable Remote Initiated.
Aux Short Circuit
A Reporting setting that sends a report to the selected report control when too much current is
and Restores
detected. A restore report is also sent when the overcurrent condition is fixed.
B
Backup Destination
A Reporting setting that configures the backup destination for the selected report control. If using
another device as the backup destination, set the reporting format in Reporting>Backup Format and
enable test report events in the backup device.
Backup Format
A Reporting setting that configures the reporting format when using another device as backup. You
must set the same reporting format on the backup device.
Battery Fault
An Options setting that indicates that there is a problem with the battery.
Bit Error Rate
An Options setting that displays the current Bit Error Rate (BER). The BER value is periodically updated
when the NX-7002 is logged into the network. This information is used for verification purposes only.
BER values range from 0% to 7%, with 99 as unknown. It is applicable to GPRS only.
Bus Power Fault
An Options setting that indicates that there is a problem with power to the bus.
C
Callback Required
An Up/download setting that configures the NX-7002 to call back the PC in order to initiate an
upload/download session. To enable this setting, you must enable Remote Initiated.
CID
Contact ID reporting protocol
Communications
A Reporting menu entry that groups together the communication events that are reported to the
selected report control.
Connection Fault
An Options menu entry that groups connection fault options. A connection fault occurs when the
module cannot log into the GSM network.
Connection Type
An Up/Download menu entry that selects a CSD or GPRS connection.
Contact ID
A Reporting menu entry that selects the Contact ID protocol.
Control Panel
A Reporting setting that configures the maximum time during which the control panel must report an
Timeout
event. If the NX-7002 report control is configured for secondary reporting and the control panel does
not report the event during this time, the report control reports the event.
This can be from 1 to 255 seconds. If set to 0, the setting is disabled.
CSD
Circuit Switched Data. This is a communication format used to upload/download data. It is similar to
a modem but it is wireless and built in to the NX-7002.
An Options menu entry that groups CSD connection options.
Current Operator
An Options setting that displays the name of the automatically or manually selected GSM network
operator. This setting is valid only when the NX-7002 is logged into the GSM network.
D
Destination
A Reporting setting that configures the report destination for the selected report control.
DHCP Assigned IP
An Options setting that displays the IP address that is assigned to the NX-7002 when it logs into the
Address
GPRS network.
DL900
A PC upload/download program for NetworX systems.
Download
The process of sending programming information or data on the panel to a PC running
upload/download software or to the central station.
Download Starting
An Options setting that indicates that downloading is about to start.