tone dialling, program a "15" in the segment where pulse dialling should begin. If the entire number
should be pulse dialling, program a "15" in the first segment. Program an "11" for a "*", and a "12"
for a "#".
Note: A zero is programmed as a "0".
LOCATION 7 - ACCOUNT CODE FOR PHONE N° 2 (6 segments of numerical data)
Use location 7 to program the account code that is sent when phone N°2 is dialled. A zero in the
account code is programmed as a "0". A "10" indicates the end of the account code, so program a
"10" in the segment immediately after the last digit of the account code. If the account code is 6
digits long, program all 6 segments. If this location is left unprogrammed, account code 1 will be
used when the second phone number is dialled.
LOCATION 8 - COMMUNICATOR FORMAT FOR PHONE N° 2 (1 segment, numerical data)
Location 8 contains the communicator format used to transmit to the receiver that is connected to
phone N°2. Consult the instruction manual for your central station receiver in order to determine
which format is compatible. See Appendix 3 for all available format selections. If you require a
format other than those listed, review the override options described in Location 18 to create the
appropriate format. In order to create a special format, a "15" must be programmed in location 8, in
addition to the entries in location 18. If this location contains a "0", format 1 will be used when
phone N°2 is dialled.
LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 2 (2 segments, numerical
data)
Segment 1, dial attempts: Segment 1 of location 9 is used to enter the number of dial attempts (1 to
15 attempts) that the communicator will make to phone N°2 before it ends the notification process.
Factory default is "0", and the communicator will make the same number of attempts as those
programmed in location 3.
Note: There will be a waiting time of 12 seconds between the first two dial attempts, and a waiting time of 60 seconds
between each subsequent dial attempt (regardless of the number dialled).
Segment 2, phone N° 2 backup control: Programming a "0" in segment 2 of this location will cause
the NX-10 to make the designated number of attempts to phone N°1 before setting the "fail to
communicate" condition and stop reporting. Programming a "1" in this segment will cause the NX-
10 to stop trying to communicate after the designated number of attempts have been made to phone
N°2. If a "2" is programmed in this segment, it will cause the NX-10 to make the dial attempts in
increments of two. The first two attempts will be made to phone N°2, the next two attempts to phone
N°1, then repeating until the total number of attempts designated in segment 1 is completed.