Removing The Power Paddle Card - IBM System x3300 M4 Installation And Service Manual

Type 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Removing the power paddle card

To remove the power paddle card, complete the following steps:
10. Loosen the screws of the hot-swap power supply cage showed as step 1 in the
11. Remove the redundant power supply cage cover showed as step 2 in the
12. Remove the power paddle card out of the redundant power supply cage
414
System x3300 M4 Type 7382: Installation and Service Guide
1. Read the safety information that begins in Safety and "Installation guidelines"
on page 36.
2. Turn off the server (see "Turning off the server" on page 24) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3. Carefully turn the server on its side so that it is lying flat, with the cover
facing up.
Attention: Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see "Removing the left-side cover" on
page 39).
5. Remove the air baffle (see "Removing the air baffle" on page 41)
6. Remove the fan assembly (see "Removing the fan assembly" on page 42)
7. Remove the redundant power supply slightly out of the server to disconnect it
from the power paddle card.
8. Disconnect all power cables from the connectors on the system board.
Disengage the power cables from any cable clips.
9. If a RAID adapter battery is installed on the chassis, disconnect the power
cable from the ServeRAID adapter.
following illustration.
following illustration.
showed as step 3 in the following illustration.
Attention: Make sure that the cage cover have been released from the tabs of
the redundant power supply cage showed as the zoom-in area in the
illustration.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents