Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
40000025-00000000
The Chassis Event
Log (CEL) on system
%1 is 75% full.(%1 =
CIM_ComputerSystem.ElementName)
40000026-00000000
The Chassis Event
Log (CEL) on system
%1 is 100% full.(%1
=
CIM_ComputerSystem.ElementName)
40000027-00000000
%1 Platform
Watchdog Timer
expired for %2.(%1 =
OS Watchdog or
Loader Watchdog;
%2 = OS Watchdog
or Loader Watchdog)
40000028-00000000
IMM Test Alert
Generated by %1.(%1
= user ID)
40000029-00000000
Security: Userid: '%1'
had %2 login failures
from an SSH client
at IP address %3.(%1
= user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in
the firmware); %3 =
IP address,
xxx.xxx.xxx.xxx)
40000030-00000000
IPv6 disabled by
user [arg1].
40000031-00000000
IPv6 static IP
configuration
enabled by user
[arg1].
40000032-00000000
IPv6 DHCP enabled
by user [arg1].
40000033-00000000
IPv6 stateless
auto-configuration
enabled by user
[arg1].
Info
The IMM event log
is 75% full. When
the log is full,
older log entries
are replaced by
newer ones.
Info
The IMM event log
is full. When the
log is full, older
log entries are
replaced by newer
ones.
Error
A Platform
Watchdog Timer
Expired event has
occurred.
Info
A user has
generated a test
alert from the
IMM.
Error
A user has
exceeded the
maximum number
of unsuccessful
login attempts
from SSH and has
been prevented
from logging in for
the lockout period.
Info
IPv6 protocol is
disabled by user.
Info
IPv6 static address
assignment method
is enabled by user.
Info
IPv6 DHCP
assignment method
is enabled by user.
Info
IPv6 statless
auto-assignment
method is enabled
by user.
To avoid losing older log entries, save
the log as a text file and clear the log.
To avoid losing older log entries, save
the log as a text file and clear the log.
1. Reconfigure the watchdog timer to a
higher value.
2. Make sure that the IMM Ethernet
over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether
device driver for the operating
system.
4. Disable the watchdog.
5. Check the integrity of the installed
operating system.
No action; information only.
1. Make sure that the correct login ID
and password are being used.
2. Have the system administrator reset
the login ID or password.
No action; information only.
No action; information only.
No action; information only.
No action; information only.