IBM System x3300 M4 Installation And Service Manual page 221

Type 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f0113-0301xxxx
A bus timeout has
occurred on system
CPU 1 PECI.
806f0113-0302xxxx
A bus timeout has
occurred on system
CPU 2 PECI
806f0413-2582xxxx
A PCI PERR has
occurred on system
%1.(%1 =
CIM_ComputerSystem.
ElementName)
806f0513-2582xxxx
A PCI SERR has
occurred on system
%1.(%1 =
CIM_ComputerSystem.
ElementName)
Error
This message is for
the use case when
an implementation
has detected a Bus
Timeout.
Error
This message is for
the use case when
an implementation
has detected a Bus
Timeout.
Error
A PCI PERR has
occurred. (Sensor =
PCIs)
Error
A PCI SERR has
occurred. (Sensor =
PCIs)
1. Reseat the microprocessor, and then
restart the server.
2. Replace microprocessor n.
(n = microprocessor number)
1. Reseat the microprocessor, and then
restart the server.
2. Replace microprocessor n.
(n = microprocessor number)
1. Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics LEDs.
2. Reseat the affected adapters and
riser cards.
3. Update the server firmware (UEFI
and IMM) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Replace the adapters.
5. Replace the riser cards.
1. Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics LEDs.
2. Reseat the affected adapters and
riser card.
3. Update the server firmware (UEFI
and IMM) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Make sure that the adapter is
supported. For a list of supported
optional devices, see
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/.
5. Replace the adapters.
6. Replace the riser cards.
Chapter 4. Troubleshooting
203

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents