Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f0007-0301xxxx
The Processor CPU n
806f0007-0302xxxx
Status has Failed
with IERR. (n =
microprocessor
number)
806f000f-22010cxx
CPU voltage
mismatch detected
on %1. (%1 =
CIM_Processor.ElementName)
182
System x3300 M4 Type 7382: Installation and Service Guide
Error
A processor failed -
IERR condition has
occurred.
Error
This message is for
the use case when
an implementation
has detected a
CPU voltage
mismatch with the
socket voltage.
1. Make sure that the latest levels of
firmware and device drivers are
installed for all adapters and
standard devices, such as Ethernet,
SCSI, and SAS.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
2. Update the firmware (UEFI and
IMM) to the latest level "Updating
the firmware" on page 111).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace
microprocessor n.
7. (Trained technician only) Replace
the system board.
(n = microprocessor number)
1. This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.