Removing A Fixed Power Supply - IBM System x3300 M4 Installation And Service Manual

Type 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Removing a fixed power supply

When you remove or install a fixed power supply, observe the following
precautions.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any component
that has this label attached. There are no serviceable parts inside these
components. If you suspect a problem with one of these parts, contact a service
technician.
To remove a fixed power supply, complete the following steps:
Note:
v If one fixed power supply is installed in the server, you must turn off the server
v You must install the fan assembly before removing or installing the power
1. Read the safety information that begins in Safety and "Installation guidelines"
2. If only one power supply is installed, turn off the server and peripheral devices
3. Loosen 4 screws from the rear side of the server and pull the fixed power
394
System x3300 M4 Type 7382: Installation and Service Guide
before removing the power supply.
supply.
on page 36.
Attention: Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
and disconnect all power cords.
supply out of the server as the illustration showed.