IBM System x3300 M4 Installation And Service Manual page 225

Type 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
80070219-0701xxxx
Sensor Sys Board
Fault has
transitioned to
critical.
806f0312-2201xxxx
Entry to aux log has
asserted.
80080128-2101xxxx
Low security jumper
presence has
asserted.
8008010f-2101xxxx
Physical presence
jumper presence has
asserted.
81030006-2101xxxx
Sig verify fail has
deasserted.
806f0028-2101xxxx
TPM command fail
has asserted.
Firmware and software messages
806f000f-220103xx
The System %1
encountered
firmware error -
unrecoverable boot
device failure. (%1 =
ComputerSystem.ElementName)
806f000f-220104xx
The System %1 has
encountered a
motherboard failure.
(%1 =
ComputerSystem.ElementName)
Error
A sensor has
changed to Critical
state from a less
severe state.
Info
Entry to aux log
has been detected.
Info
The low security
jumper has been
detected.
Info
The physical
presence jumper
has been detected.
Info
The sig verify fail
has deasserted.
Warning
The TPM sensor
access has been
degraded or
unavailable.
Error
This message is for
the use case when
an implementation
has detected that
System Firmware
Error
Unrecoverable boot
device failure has
occurred.
Error
This message is for
the use case when
an implementation
has detected that a
fatal motherboard
failure in the
system.
1. Check the system-event log.
2. Check for an error LED on the
system board.
3. Replace any failing device.
4. Check for a server firmware update.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5. (Trained technician only) Replace
the system board.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
1. Turn off the server and disconnect it
from power.
2.
1. This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.
1. This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.
Chapter 4. Troubleshooting
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents