Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f070c-2581xxxx
Memory DIMM
Configuration Error
for One of the
DIMMs.
806f070c-2581xxxx
Memory DIMM
Configuration Error
for All DIMMs.
806f090c-2001xxxx
Memory DIMM for
806f090c-2002xxxx
DIMM n Status has
806f090c-2003xxxx
been automatically
806f090c-2004xxxx
throttled. (n = DIMM
806f090c-2005xxxx
number)
806f090c-2006xxxx
806f090c-2007xxxx
806f090c-2008xxxx
806f090c-2009xxxx
806f090c-200axxxx
806f090c-200bxxxx
806f090c-200cxxxx
806f0a0c-2001xxxx
An
806f0a0c-2002xxxx
Over-Temperature
806f0a0c-2003xxxx
condition has been
806f0a0c-2004xxxx
detected on the
806f0a0c-2005xxxx
DIMM n Status. (n =
806f0a0c-2006xxxx
DIMM number)
806f0a0c-2007xxxx
806f0a0c-2008xxxx
806f0a0c-2009xxxx
806f0a0c-200axxxx
806f0a0c-200bxxxx
806f0a0c-200cxxxx
800b010c-2581xxxx
Backup Memory
redundancy lost has
asserted.
800b030c-2581xxxx
Backup Memory
sufficient resources
from redundancy
degraded has
asserted.
800b050c-2581xxxx
Backup Memory
insufficient resources
has asserted.
Recovery messages
Error
A memory DIMM
configuration error
has occurred.
Error
A memory DIMM
configuration error
has occurred.
Warning
A memory DIMM
has been throttled.
Error
An
over-temperature
condition has
occurred for
DIMM n. (n =
DIMM number)
Error
Redundancy has
been lost.
Warning
There is no
redundancy. The
state has been
transitioned from
redundancy to
sufficient resources.
Error
There is no
redundancy and
insufficient to
continue operation.
Make sure that DIMMs are installed in
the correct sequence and have the same
size, type, speed, and technology.
Make sure that DIMMs are installed in
the correct sequence and have the same
size, type, speed, and technology.
1. Reseat the DIMM, and then restart
the server.
2. Replace DIMM n.
(n = DIMM number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Make sure that ambient temperature
is within the specifications.
3. If a fan has failed, complete the
action for a fan failure.
4. Replace DIMM n.
(n = DIMM number)
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirroring in the Setup
utility.
Chapter 4. Troubleshooting