Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Memory DIMM n
Status Scrub failure
detected. (n = DIMM
number)
806f040c-2001xxxx
Memory DIMM
806f040c-2002xxxx
disabled for DIMM n
806f040c-2003xxxx
Status. (n = DIMM
806f040c-2004xxxx
number)
806f040c-2005xxxx
806f040c-2006xxxx
806f040c-2007xxxx
806f040c-2008xxxx
806f040c-2009xxxx
806f040c-200axxxx
806f040c-200bxxxx
806f040c-200cxxxx
194
System x3300 M4 Type 7382: Installation and Service Guide
Error
A memory scrub
failure has been
detected.
Info
DIMM disabled.
1. (Trained technician only) Remove
the affected microprocessor and
check the microprocessor socket
pins for any damaged pins. If a
damage is found, replace the system
board (see "Removing the system
board" on page 428 and "Replacing
the system board" on page 430).
2. (Trained technician only) Swap the
affected microprocessor, if there are
more than one microprocessor
installed. If the problem follows the
microprocessor, replace the affected
microprocessor (see "Removing a
microprocessor and heat sink" on
page 416 and "Installing a memory
module" on page 62).
3. (Trained technician only) Replace
the system board (see "Removing
the system board" on page 428 and
"Replacing the system board" on
page 430).
1. Make sure the DIMM is installed
correctly (see "Installing a memory
module" on page 62).
2. If the DIMM was disabled because
of a memory fault (memory
uncorrectable error or memory
logging limit reached), follow the
suggested actions for that error
event and restart the server.
3. Check the IBM support website for
an applicable retain tip or firmware
update that applies to this memory
event. If no memory fault is
recorded in the logs and no DIMM
connector error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).