Table 1. Server features and specifications (continued)
RAID controllers:
v ServeRAID C105 supports up to
eight SATA ports
– support for RAID level 0, 1 and
10
– support 3.5-inch SATA 3TB
HDDs
– support HDD Simple swap and
Hot swap
– support 4 SATA HDDs in
default (can be upgraded to 8
SATA HDDs via FoD key)
Note:
v In 2.5" system, two internal SAS
cable connecting SAS RAID
controller to SAS hard drive
backplane. One type of backplanes
will be used to support eight 2.5"
hot -swap HDDs. In addition, the
system will use 2 types of
backplanes to support sixteen 2.5
hot-swap HDDs.
v In 3.5" system, two internal SAS
cable is required to support eight
3.5" hot-swap HDDs with the
required backplane.
PCI and PCI-X expansion slots:
v Six PCI-e expansion slots on the
system board
– Slot 1: PCI Express 3.0 x8;
full-height, half-length (requires
second processor)
– Slot 2: PCI Express 3.0 x8 ;
full-height, full-length
– Slot 3: PCI Express 3.0 x8 (x4
wired); full-height, half-length
– Slot 4: PCI Express 3.0 x16 (x8
wired); full-height, full-length
– Slot 5: Gen2 PCI Express x4 (x1
wired); full-height, half-length
– Slot 6: Gen2 PCI Express x8 (x4
wired); full-height, half-length,
has PCI-X capability by using a
PCI-e (of IBM System x3500 M4
TYpe 7383) to PCI-X converter
kit
v One PCI-X Slot (optional):
64-bit/133MHz
Environment:
The IBM System X3300 compute
node complies with ASHRAE class
A3 specifications.
v Power on:
– Temperature: 5°C - 40°C (41°F -
104°F) up to 950mm (3,117ft)
Above 950m, de-rated
maximum air temperature 1C /
175m
– Humidity, non-condensing:
-12°C dew point (10.4°F) and 8%
- 85% relative humidity
– Maximum dew point: 24°C
(75°F)
– Maximum altitude: 3050 m
(10,000 ft) & 5°C - 28°C (41°F -
82°F)
– Maximum rate of temperature
change: 5°C/hr (41°F/hr) for
tape drive, 20°C/hr (68°F/hr)
for HDDs
v Power off:
– Temperature: 5°C to 45°C (41°F -
113°F)
– Relative humidity: 8% - 85%
– Maximum dew point: 27°C
(80.6°F)
v Storage (non-operating)
– Temperature: 1°C to 60°C
(33.8°F - 140°F)
– Altitude: 3050 m (10,000 ft)
– Relative humidity: 5% - 80%
– Maximum dew point: 29°C
(84.2°F)
v Shipment (non-operating)
– Temperature: -40°C to 60°C
(-40°F - 140°F)
– Altitude: 10,700 m (35,105 ft)
– Relative humidity: 5% - 100%
– Maximum dew point: 29°C
(84.2°F)
v Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
Particulate contamination.
Chapter 1. The IBM System x3300 M4 Type 7382 server
Heat output:
Approximate heat output in British
thermal units (Bts):
v Minimum configuration: 392 Btu
per hour (ac 115 watts)
v Maximum configuration: 2900 Btu
per hour (ac 850 watts)
Integrated functions:
v Integrated Management Module II
(IMM2), which provides service
processor control and monitoring
functions, video controller, and
remote keyboard, video, mouse,
and remote hard disk drive
capabilities
v Onboard Intel Powerville Gigabit
Ethernet controller with Wake on
LAN support. The controller
provides up to four ports when the
optional Feature on Demand (FoD)
feature is activated.
v Combine "Intel PCH SAS/SATA
RAID controller which supports
for RAID levels 0, 1 and 10 with
SW RAID controller - ServeRAID
C105
v Light path diagnostics
v Eight Universal Serial Bus (USB)
2.0 ports:
– Two on the front of the chassis
– Four on the rear of the chassis
– Two internal USB ports: one is
for option USB flash device with
embedded hypervisor, one is for
option USB tape drive
v One serial connector
v One D-Sub VGA connector
Power supply:
v One fixed 460-watt power supply
– None support AEM function
– None support graphic card
– For two microprocessors
installed, the maximum HDD is
up to 4 and the maximum PCIe
cards is up to 3
v Up to two hot-swap power supply
for redundant supply
– 550-watt ac
Note:
1. None support graphic card
2. The maximum PCIe card is
up to 3 when two
microprocessors installed for
550-watt ac.
– 750-watt ac
7