v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
I.2018002
[I.2018002] The device found at
Bus % Device % Function %
could not be configured due to
resource constraints. The
Vendor ID for the device is %
and the Device ID is %.
I.2018003
[I.2018003] A bad option ROM
checksum was detected for the
device found at Bus % Device
% Function %. The Vendor ID
for the device is % and the
Device ID is %.
S.3020007 [S.3020007] A firmware fault
has been detected in the UEFI
image.
S.3028002 [S.3028002] Boot permission
timeout detected.
S.3030007 [S.3030007] A firmware fault
has been detected in the UEFI
image.
168
System x3300 M4 Type 7382: Installation and Service Guide
Description
OUT_OF_RESOURCES (PCI
Option ROM).
ROM CHECKSUM ERROR.
Internal UEFI Firmware Fault
Detected, System halted.
Boot Permission Negotiation
Timeout.
Internal UEFI Firmware Fault
Detected, System halted.
Action
1. Run the Setup utility (see "Using
the Setup utility" on page 115).
Select Startup Options from the
menu and modify the boot
sequence to change the load order
of the optional-device ROM code.
2. Informational message that some
devices might not be initialized.
3. See retain tip H197144
(http://www-947.ibm.com/
support/entry/portal/
docdisplay?lndocid=migr-5084743)
for more information.
1. Check the riser-card LEDs.
2. Reseat all affected adapters and
riser cards.
3. Move the affected adapter to a
different slot.
4. Update the PCI adapter firmware.
5. Replace the affected adapters and
riser cards.
1. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this error.
2. Recover the server firmware.
3. (Trained technician only) replace
the system board.
1. Check the IMM2 error messages
for communication errors and
follow the actions.
2. Restart the server.
3. If the problem remains, contact
your IBM service representative
for support.
1. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this error.
2. Recover the server firmware.
3. (Trained technician only) Replace
the system board.