Table 18. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
80010701-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper
non-critical) has
asserted.
80010901-0701xxxx
Numeric sensor
adapter Ambient
Temp going high
(upper critical) has
asserted.
80010901-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper critical)
has asserted.
80010b01-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper
non-recoverable) has
asserted.
81010701-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper
non-critical) has
deasserted.
81010901-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper critical)
has deasserted.
81010b01-0c01xxxx
Numeric sensor
Ambient Temp going
high (upper
non-recoverable) has
deasserted.
80010701-1401xxxx
Sensor CPU n VR
80010701-1402xxxx
Temp going high
(upper non-critical)
has asserted. (n =
microprocessor
number)
80010901-1401xxxx
Sensor CPU n VR
80010901-1402xxxx
Temp going high
(upper critical) has
asserted. (n =
microprocessor
number)
174
System x3300 M4 Type 7382: Installation and Service Guide
Warning
An upper
non-critical sensor
going high has
asserted.
Error
An upper critical
sensor going high
has asserted.
Error
An upper critical
sensor going high
has asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Info
An upper
non-critical sensor
going high has
deasserted.
Info
An upper critical
sensor going high
has deasserted.
Info
An upper
non-recoverable
sensor going high
has deasserted.
Warning
An upper
non-critical sensor
going high has
asserted.
Error
An upper critical
sensor going high
has asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
No action; information only.
No action; information only.
No action; information only.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air
from exiting the server.