IBM System x3300 M4 Installation And Service Manual page 283

Type 7382
Hide thumbs Also See for System x3300 M4:
Table of Contents

Advertisement

Table 19. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
v Go to the IBM support web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
202-801-xxx
Memory
202-802-xxx
Memory
State
Description
Memory
Aborted
Internal program
Stress Test
error.
Memory
Failed
General error:
Stress Test
memory size is
insufficient to
run the test.
Action
1. Turn off and restart the system.
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
3. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 111.
4. Run the test again.
5. Turn off and restart the system if
necessary to recover from a hung state.
6. Run the memory diagnostics to identify
the specific failing DIMM.
7. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Make sure that all memory is enabled by
checking the Available System Memory in
the Resource Utilization section of the
DSA event log. If necessary, enable all
memory in the Setup utility (see
"Updating the firmware" on page 111).
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
3. Run the test again.
4. Run the standard memory test to validate
all memory.
5. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 4. Troubleshooting
265

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents