Configuring the Broadcom NetXtreme Gigabit Ethernet controller ..41 Updating IBM Director ..... 42 Setting up a Remote Supervisor Adapter II SlimLine ..42 Chapter 3.
Page 6
General problems ..... . 134 Hard disk drive problems....134 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 7
Hardware service and support ....224 IBM Taiwan product service ....224 Appendix B.
Page 8
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Use the information in this section to help you identify potential unsafe conditions in an IBM product that you are working on. Each IBM product, as it was designed and manufactured, has required safety items to protect users and service technicians from injury.
Page 11
v Do not touch the reflective surface of a dental mirror to a live electrical circuit. The surface is conductive and can cause personal injury or equipment damage if it touches a live electrical circuit. v Some rubber floor mats contain small conductive fibers to decrease electrostatic discharge.
Be sure to read all caution and danger statements in this documentation before you perform the procedures. Read any additional safety information that comes with the server or optional device before you install the device. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 13
Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet.
Page 14
Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Page 15
Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
Page 16
The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 17
Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
Page 18
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your server.
Features and specifications The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply. Chapter 1. Introduction...
Page 22
– Server on: 8% to 80% levels indicate an upper limit, below – Server off: 8% to 80% which a large number of computers will operate. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Server controls, LEDs, and connectors This section describes the controls, light-emitting diodes (LEDs), and connectors on the front and rear of the server. Front view The following illustration shows the 2.5-inch hard disk drive server model. USB 3 connector Operator information USB 4 connector Rack release latch panel...
Page 24
– System-locator LED: Use this blue LED to visually locate the server among other servers. You can use IBM Director to light this LED remotely. This LED is controlled by the BMC. – System-error LED: When this amber LED is lit, it indicates that a system error has occurred.
LED itself has failed. v System-locator LED: Use this LED to visually locate the server among other servers. You can use IBM Director to light this LED remotely. v Video connector: Connect a monitor to this connector. The video connectors on the front and rear of the server can be used simultaneously.
(some models) Mini-SAS/SATA controller connector Microprocessor connector IDE connector Fan 2 connector Operator information panel connector Fan 5 connector Video connector Fan 4 connector USB connectors Fan 3 connector IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Power backplane card internal connectors The following illustration shows the internal connectors on the power backplane card. Power-supply connectors System-board connector Hard disk drive power connector Chapter 1. Introduction...
Pins 2 and 3: Clear the CMOS data, which clears the power-on password and administrator password Boot block recovery (JP4) v Pins 1 and 2: Normal (default). v Pins 2 and 3: Recover boot block IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
System-board external connectors The following illustration shows the external connectors on the system board. Ethernet connector USB 1 connector Systems- management USB 2 connector Ethernet 2 connector Serial connector Ethernet 1 connector Video connector Chapter 1. Introduction...
Fan 2 error LED DIMM 1 error DIMM 2 error Fan 5 error LED DIMM 3 error Fan 4 error LED DIMM 4 error Fan 3 error LED IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Updating the firmware The firmware in the server is periodically updated and is available for download on the Web. Go to http://www.ibm.com/systems/support/ to check for the latest level of firmware, such as BIOS code, device drivers, and service processor firmware.
IBM Director IBM Director is a workgroup-hardware-management tool that you can use to centrally manage System x servers. If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director update and interim fixes.
Page 35
Configuration/Setup Utility menu choices The following choices are on the Configuration/Setup Utility main menu. Depending on the version of the BIOS code, some menu choices might differ slightly from these descriptions. v System Summary Select this choice to view configuration information, including the amount of installed memory.
Page 36
Select this choice to view the system resources that are used by installed PCI Express devices, configure PCI interrupt routing, and enable or disable PCI ROM Control Execution. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 37
– RSA II Settings Select this choice to view and change Remote Supervisor Adapter II SlimLine settings. Select Save Values and Reboot RSA II to save the changes that you make in the settings and restart the Remote Supervisor Adapter II SlimLine.
Page 38
Select Clear System Logs to clear the system event/error log. – RSA II Event/Error Log This choice is available only if an optional Remote Supervisor Adapter II SlimLine is installed. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 39
Select this choice to view the error messages in the Remote Supervisor Adapter II event/error log. Use the arrow keys to move among pages in the log. Select Clear RSA II logs to clear the Remote Supervisor Adapter II event/error log. The Remote Supervisor Adapter II event/error log contains all event and error messages that have been generated during POST, by the system interface handler, and by the system service processor.
Page 40
CMOS jumper on the system board to pins 2 and 3 to clear CMOS memory and bypass the power-on or administrator password check. The jumper location is shown in the following illustration. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Boot block recovery (JP4) Clear CMOS (JP1) To clear CMOS memory and reset the passwords, complete the following steps: 1. Review the safety information that begins on page vii. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables.
When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can use the CD to configure any supported IBM server model. The setup program provides a list of tasks that are required to set up your server model.
ServerGuide program to install your operating system, complete the following steps to download the latest operating-system installation instructions from the IBM Web site. Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/.
Starting the LSI Logic Configuration Utility program To start the LSI Logic Configuration Utility program, complete the following steps: 1. Turn on the server. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
2. When the prompt Press CTRL-C to start LSI Logic Configuration Utility..is displayed, press Ctrl+C. If you have set an administrator password, you are prompted to type the password. 3. To select a controller (channel) from the list of adapters, use the arrow keys and press Enter.
Select Advanced Setup; then, select Baseboard Management Controller (BMC) Settings. f. Select System-BMC Serial Port Sharing and set it to Enabled. g. Select BMC Serial Port Access Mode and set it to Shared. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 47
h. Press Esc to exit the BMC Serial Port Access Mode section of the Baseboard Management Controller (BMC) Settings. i. Press Esc to exit Baseboard Management Controller (BMC) Settings. j. Select Save Settings; then, press Enter. k. Press Enter to continue. l.
Page 48
The following examples show the original content of the /etc/lilo.conf file and the content of this file after modification. Original /etc/lilo.conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.b message=/boot/message linear image=/boot/vmlinuz-2.4.9-e.12smp label=linux initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 image=/boot/vmlinuz-2.4.9-e.12 label=linux-up initrd=/boot/initrd-2.4.9-e.12.img read-only root=/dev/hda6 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 49
Modified /etc/lilo.conf contents prompt timeout=50 default=linux-Monitor boot=/dev/hda #map=/boot/map install=/boot/boot.b #message=/boot/message linear # This will allow you to only Monitor the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Monitor initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 append="console=ttyS0,19200n8 console=tty1" # This will allow you to Interact with the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Interact initrd=/boot/initrd-2.4.9-e.12smp.img...
Page 50
Red Hat Enterprise Linux ES (2.4.9-e.12smp) root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 initrd /initrd-2.4.9-e.12smp.img title Red Hat Enterprise Linux ES-up (2.4.9-e.12) root (hd0,0) kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6 initrd /initrd-2.4.9-e.12.img IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 51
Modified /boot/grub/grub.conf contents #grub.conf generated by anaconda # Note that you do not have to rerun grub after making changes to this file # NOTICE: You have a /boot partition. This means that all kernel and initrd paths are relative to /boot/, eg. root (hd0,0) kernel /vmlinuz-version ro root=/dev/hda6 initrd /initrd-version.img...
Page 52
# This will allow you to Interact with the OS boot via SOL title linux SOL Interactive kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=tty1 console=ttyS0,19200 initrd (hd0,1)/boot/initrd title floppy IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 53
Modified /boot/grub/menu.lst contents Notes root chainloader +1 title failsafe kernel (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.shipped Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line. You must restart the Linux operating system after you complete these procedures for the changes to take effect and to enable SOL.
OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the drive. The InstallShield wizard starts, and a window similar to that shown in the following illustration opens. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 55
Linux operating system. You must be logged in as a root user to perform these procedures. 1. Go to http://www.ibm.com/systems/support/. Download the utility program and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the drive.
2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click IBM System x3350 to display the matrix of downloadable files for the server. 5. From the BMC software, copy the files bmc.exe and Init.ini to a setup utility diskette.
Page 57
2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click IBM System x3350 to display the matrix of downloadable files for the server. 5. From the BMC software, copy the file bmc_cfg.exe to a configuration utility diskette.
Page 58
2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click IBM System x3350 to display the matrix of downloadable files for the server. 5. From the BMC software, copy the file fsloader.exe to an SDR/FRU update diskette.
1. Go to http://www.ibm.com/systems/support/ 2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click IBM System x3350 to display the matrix of downloadable device driver files for the server. Chapter 2. Configuration information and instructions...
Updating IBM Director If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director updates and interim fixes. To install the IBM Director updates and any other applicable updates and interim fixes, complete the following steps.
Firmware-update utility program To download and install the software and firmware, complete the following steps. Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/.
4. Click System x3350 to display the matrix of downloadable files for the server. 5. Select the software or firmware package that you want to install. On the next page, click the link for each file that you want to download. Follow the instructions that are displayed.
4193 servers. For an updated parts listing on the Web, complete the following steps. Note: Changes are made periodically to the IBM Web site. the actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/ 2.
Page 64
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your server.
Page 66
39M4375 B2x) (type 4193 models 44x, 52x, B2x, E5x) Simple-swap filler panel, 3.5-inch (type 4192 models 32x, 39M4343 42x, B4x, E1x, E3x) (type 4193 models 32x, 42x, B4x) IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 67
DVD-drive, Rambo 4.5 (optional) 39M3567 DVD-drive, RAM Rambo 5 (optional) 42C0955 DVD-drive, RAM Rambo 5 (optional) 42C0959 PCI-E 4 GB single port fiber channel host bus adapter 39R6526 (optional) Chapter 3. Parts listing, System x3350 Type 4192 and 4193 server...
Page 68
NetXtreme II 1000 express dual port ethernet adapter 42C1782 (optional) NetXtreme II 10 GB express fiber SR adapter (optional) 42C1792 PRO/1000 PT dual port server adapter (optional) 39Y6128 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Edition 1-4 Processors Japanese Microsoft Windows Server 2003 R2 w/SP2 32bit Standard 44W4053 Edition 1-4 Processors Simplified Chinese Microsoft Windows Server 2003 R2 w/SP2 32bit Standard 44W4054 Edition 1-4 Processors Korean Chapter 3. Parts listing, System x3350 Type 4192 and 4193 server...
Page 70
Edition 1-2 Processors Japanese Microsoft Windows Server 2003 R2 w/SP2 Enterprise x64 44W4076 Edition 1-8 Processors English Microsoft Windows Server 2003 R2 w/SP2 Enterprise x64 44W4077 Edition 1-8 Processors Japanese IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
1-8 Processor Traditional Chinese Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
Page 72
Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela 39M5219 Korea (Democratic People’s Republic of), Korea (Republic of) 39M5199 Japan IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 73
IBM power cord part number Used in these countries and regions 39M5068 Argentina, Paraguay, Uruguay 39M5226 India 39M5233 Brazil Chapter 3. Parts listing, System x3350 Type 4192 and 4193 server...
Page 74
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your server.
When you are finished working on the server, reinstall all safety shields, guards, labels, and ground wires. v For a list of supported optional devices for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. System reliability guidelines...
Working inside the server with the power on Attention: Static electricity that is released to internal server components when the server is powered-on might cause the server to halt, which might result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when you work inside the server with the power on.
USB 3 connector USB 4 connector Video connector Rear View Power-supply connector Ethernet 1 Video connector USB 2 Ethernet 2 USB 1 Systems- Serial management Ethernet connector connector IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Removing and replacing Tier 1 CRUs Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. The illustrations in this document might differ slightly from your hardware.
4. Tighten the thumbscrew until the cover correctly engages all the inset tabs on the server. Thumbscrew Fan door 5. Slide the server into the rack. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Removing the side air baffle To remove the air baffle that is closest to the wall of the server, complete the following steps: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables.
57. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables. 3. Remove the cover (see “Removing the cover” on page 61). IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Air baffle Baffle pins Cable routing slot Baffle mounting holes 4. Lift the baffle up slightly, making sure that the pins come out of the holes on the system board. 5. Slide the cable out of the cable routing slot. Make sure that you do not disconnect or loosen the cable.
3. Remove the cover (see “Removing the cover” on page 61). 4. If an adapter is installed in the riser-card assembly, disconnect any cables that are connected to the adapter. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Expansion slot cover PCI Express adapter Adapter support bracket Expansion Riser-card slot assembly Riser-card connector 5. Grasp the riser-card assembly at the rear edge and lift to remove it. 6. If there is an adapter in the riser-card assembly, remove it. 7.
8. If you are instructed to return the adapter, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Installing an adapter To install the replacement adapter, complete the following steps. 1. Route the adapter cables, if any, before you install the adapter. Route the cables so that they are not on top of components or blocking the airflow from the fans.
1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. 2. Position the Remote Supervisor Adapter II SlimLine so that the connector on the adapter aligns with the connector on the system board. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 89
Remote Supervisor Adapter II SlimLine Rear mounting bracket Front mounting bracket retention latch Front mounting bracket 3. At a downward angle, slip the back end of the adapter under the tab on the rear mounting bracket, aligning the holes in the adapter with the posts on the rear mounting bracket.
6. Pull the drive out of the front of the server. 7. Remove the retention clip from the side of the drive. Save the clip to use when you install the replacement drive. Drive-retention clip Alignment pins IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 91
8. If you are instructed to return the CD-RW/DVD drive, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing the CD-RW/DVD drive To install the replacement CD-RW/DVD drive, complete the following steps: 1.
Page 92
To avoid damage to the hard disk drive connectors, make sure that the server cover is in place and fully closed whenever you install or remove a hard disk drive. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
The following illustration show the 2.5-inch hard disk drive server model. SAS hard disk drive backplane Drive-tray assembly Drive handle The following illustration shows the 3.5-inch hard disk drive server model. Hard disk drive assembly Drive handle 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57.
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables. 3. Open the fan door. 4. Remove the CD-RW/DVD drive (see “Removing a CD-RW/DVD drive” on page 72). IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
CD-RW/DVD drive cable retainer 5. Slide the CD-RW/DVD drive cable retainer away from the interposer card. Mounting screws Interposer card CD-RW/DVD drive 6. Remove the two mounting screws from the interposer card and disconnect the CD-RW/DVD drive cable; then, remove the interposer card. 7.
1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. 2. Turn off the server and peripheral devices and disconnect the power cord and all external cables. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
DIMMs: v The server supports up to four DIMMs for system memory. See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of memory modules that you can use with the server. Note: Because some memory is reserved for system operation, the actual usable memory size that is reported by the operating system is less than the total installed size.
Page 98
DIMM 4 Single-rank Single-rank Single-rank Single-rank Single-rank Single-rank Double-rank Double-rank Recommend this configuration as the first choice. Double-rank Double-rank Single-rank Single-rank Recommend this configuration as the second choice. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 99
Table 6. Interleave Mode DIMM slot population (continued) First pair Second pair Remarks Double-rank Double-rank Double-rank Double-rank v When you install or remove DIMMs, the server configuration information changes. When you restart the server, the system displays a message that indicates that the memory configuration has changed.
2. Touch the static-protective package that contains the controller to any unpainted metal surface on the server. Then, remove the controller from the static-protective package. Avoid touching the components and gold-edge connectors on the controller. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Expansion- slot cover Optional ServeRAID-MR10i SAS/SATA controller Riser-card assembly Expansion slot Riser-card connector 3. Insert the controller into the riser-card assembly, aligning the connector on the controller with the connector on the riser-card assembly. Press the controller firmly into the riser-card assembly. Make sure that the controller snaps securely into the riser-card assembly.
6. If you are instructed to return the power supply, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing a power supply Statement 8: IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
To ensure proper server operation, replace a failed fan within 48 hours. To install the replacement hot-swap fan, complete the following steps: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
2. Orient the new fan in the same position as the fan that you removed. Make sure that the airflow indicator, on the top of the fan, is pointing to the rear of the server Fan 2 A IR A IR Fan 3 Fan 4 Fan 5...
Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
See “Using the Configuration/Setup Utility program” on page 16 for details. Removing and replacing Tier 2 CRUs You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your server.
Page 108
5. Align the holes in the top of the drive cage with the holes in the top of the chassis; then, insert the screws that secure the drive cage to the chassis. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 109
6. Install the removed drives (see “Removing and installing internal drives” on page 72). 7. Install the cover (see “Installing the cover” on page 62). 8. Slide the server into the rack. 9. Reconnect the external cables and the power cords. 10.
89). 5. Remove fan number 3 (see “Removing a hot-swap fan assembly” on page 85). 6. Disconnect the video cable from the connector on the system board. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Mounting screws Video cable screws Media bezel 7. Remove the two mounting screws in the top of the media bezel. 8. Rotate the media bezel downward to disengage it from the chassis and carefully pull the video cable out of the server. Remove the cable and the bezel from the server.
To install the replacement mini-SAS/SATA controller, complete the following steps: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57 2. Grasp the edges of the SAS/SATA controller. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 113
Notches Mini-SAS/SATA controller 3. Gently insert the controller into the SAS/SATA controller connector on the system board (see “System-board internal connectors” on page 8 for the location of the connector) while you align the holes in the controller with the two plastic alignment pins on the system board.
Installing the 3.5-inch SAS/SATA hot-swap backplane or SATA simple-swap backplate To install the replacement 3.5-inch SAS/SATA hot-swap backplane or SAS simple-swap backplate, complete the following steps. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
3.5-inch backplane/backplate Mounting channel Locking tab Mounting channel Drive bay 0 Drive bay 1 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. 2. Connect the power cable to the backplane or backplate. 3.
To install the replacement 2.5-inch SAS backplane, complete the following steps: Power cable 2.5 in. disk drive backplane Locking tab Mounting channel Signal cable Locking tab Mounting channel 2.5 in. disk drive cage IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
1. Read the safety information that begins on page vii and “Installation guidelines” on page 57 2. Connect the power cable and signal cable to the replacement backplane. 3. Insert the backplane into the drive cage. Press firmly until the backplane is fully seated and the locking tabs snap into place.
4. Remove the power supplies from the power-supply bays (see “Removing a power supply” on page 83). 5. Disconnect the hard disk drive power cable connected to the power backplane. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 119
Power backplane 6. Slide the power backplane to the left, disconnecting it from the system board. 7. Lift the power backplane out of the server. 8. If you are instructed to return the power backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
6. Install the cover (see “Installing the cover” on page 62). 7. Slide the server into the rack. 8. Reconnect the external cables and the power cords. 9. Turn on the peripheral devices and the server. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Removing and replacing FRUs FRUs must be replaced or installed only by trained service technicians. The illustrations in this document might differ slightly from the hardware. Removing a microprocessor Attention: v Do not allow the thermal grease on the microprocessor and heat sink to come in contact with anything.
2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click System x3350 to display the matrix of downloadable files for the server. v The microprocessor uses an integrated voltage regulator on the system board.
Page 123
1. Read the safety information that begins on page vii and “Installation guidelines” on page 57 Microprocessor Alignment marks Microprocessor socket dust cover Microprocessor - release lever 2. Align the microprocessor with the socket (note the alignment mark and the position of the notches);...
Note: 0.01mL is one tick mark on the syringe. If the grease is properly applied, approximately half of the grease will remain in the syringe. 6. Install the heat sink onto the microprocessor as described in “Installing a microprocessor” on page 104. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Removing the operator information panel assembly To remove the operator information panel, complete the following steps: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Installing the operator information panel assembly To install the replacement operator information panel, complete the following steps: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 57. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 127
CD-RW/DVD cable connector Video cable connector Air baffle USB cable Operator information connector panel cable connector Fan 3 Interposer card Operator information panel cable CD-RW/DVD cable Video cable USB cable 2. From the front of the server, thread the operator-information-panel ribbon cable through the panel housing in the server;...
68 and “Removing a Remote Supervisor Adapter II SlimLine” on page 70). 7. Remove the mini-SAS/SATA controller, if one is installed (see “Removing the mini-SAS/SATA controller (hot-swap models)” on page 94. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 129
8. Disconnect all cables from the system board. Make a list of each cable as you disconnect it; you can then use this as a checklist during system-board installation. Attention: In the following step, do not allow the thermal grease to come in contact with anything.
2. Align the system board with the chassis and install the eight screws that you removed previously. 3. Install the microprocessor and microprocessor heat sink (see “Installing a microprocessor” on page 104). IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 131
4. Slide the power backplane toward the system board until the connectors mate (see “Installing the power backplane” on page 102). 5. Install the power supplies (see “Installing a power supply” on page 84). 6. Reconnect the system-board cables that you disconnected in step 8 in “Removing the system board”...
Page 132
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
“Diagnostic programs and messages” on page 152 for more information. v IBM Electronic Service Agent IBM Electronic Service Agent is a software tool that monitors the server for hardware error events and automatically submits electronic service requests to the IBM Support Center. Also, it can collect and transmit system configuration information on a scheduled basis so that the information is available to you and your support representative.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are CRUs and which components are FRUs.
Page 135
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are CRUs and which components are FRUs.
Page 136
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are CRUs and which components are FRUs.
Page 137
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are CRUs and which components are FRUs.
Supervisor Adapter II SlimLine, select Event/Error logs, and then select RSA II Event/Error Log. This choice is available only if an optional Remote Supervisor Adapter II is installed. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 140
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 141
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 142
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 143
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 144
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 145
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 146
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 147
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 148
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Checkout procedure The checkout procedure is the sequence of tasks that you must follow to diagnose a problem in the server. About the checkout procedure Before you perform the checkout procedure for diagnosing hardware problems, review the following information: v Read the safety information that begins on page vii. v The diagnostic programs provide the primary methods of testing the major components of the server, such as the system board, Ethernet controller, keyboard, mouse (pointing device), serial ports, and hard disk drives.
“Solving undetermined problems” on page 220 Find the beep code in “POST beep codes” on page 116; if necessary, see “Solving undetermined problems” on page 220. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 158
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 165
2. To view the light path diagnostics panel, press the release latch on the front of the light path operator information panel to the left; then, slide it forward. This reveals the light path diagnostics panel. Lit LEDs on this panel indicate the type of error that has occurred.
The following table describes the LEDs on the light path diagnostics panel and suggested actions to correct the detected problems. Note: Check the system event/error log or BMC system event log for additional information before you replace a FRU. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 167
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 168
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
You can output all of the collected XML file that you can send to the IBM service and support, view the information locally through a generated text report file, or copy the log to a removable media and view the log from a Web browser.
7. Select CD-ROM as the first startup device. 8. Press Esc twice to return to the Configuration/Setup Utility menu. 9. Insert the IBM Dynamic System Analysis Pre-Boot Diagnostics CD into the CD or DVD drive. 10. Select Save & Exit Setup and follow the prompts. The diagnostic programs start.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 174
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 175
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 176
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 177
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 178
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 179
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 180
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 181
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 182
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 183
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 184
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 185
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 186
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 187
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 188
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 189
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 190
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 191
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 192
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 193
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 194
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 195
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 196
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 197
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 198
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 199
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 200
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 201
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 202
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 203
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 204
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 205
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 206
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 207
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 208
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 209
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 210
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 211
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 212
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 213
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 214
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 215
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 216
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 217
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 218
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 219
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 220
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 221
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 222
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 223
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 224
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 225
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 226
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 227
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 228
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 229
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 230
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
2. Under Product Support, click System x. 3. Under Popular links, click Software and device drivers. 4. Click System x3350 to display the matrix of downloadable files for the server. 5. Select the applicable file for your operating environment and the file type for the medium you want to use;...
Each message contains date and time information, and it indicates the source of the message (POST/BIOS or the service processor). IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 233
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 234
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 235
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 236
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, System x3350 Type 4192 and 4193 server,” on page 45 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
The following minimum configuration is required for the server to start: v Microprocessor v Two 512 MB DIMMs v One power supply v Power backplane v Power cord v ServeRAID SAS controller (some models) IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Because of the variety of hardware and software combinations that you can encounter, use the following information to assist you in problem determination. If possible, have this information available when you request assistance from IBM. v Machine type and model...
Page 240
IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This section contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your system, and whom to call for service, if it is necessary.
You can find service information for IBM systems and optional devices at http://www.ibm.com/systems/support/. Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with System x and xSeries servers, BladeCenter products, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, see http://www.ibm.com/services/sl/products/.
Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
(TI) que reciclen responsablemente sus equipos cuando éstos ya no les sean útiles. IBM dispone de una serie de programas y servicios de devolución de productos en varios países, a fin de ayudar a los propietarios de equipos a reciclar sus productos de TI.
United States, go to http://www.ibm.com/ibm/environment/ products/index.shtml or contact your local waste disposal facility. In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment.
For proper collection and treatment, contact your local IBM representative. This notice is provided in accordance with Royal Decree 106/2008 of Spain: The retail price of batteries, accumulators, and power cells includes the cost of the environmental management of their waste.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. European Community contact: IBM Technical Regulations Pascalstr. 100, Stuttgart, Germany 70569 Telephone: 0049 (0)711 785 1176 Fax: 0049 (0)711 785 1283 E-mail: tjahn@de.ibm.com...
Page 252
21 installing 90 expansion bays 4 removal 89 diskette drive specifications 3 display problems 139 fans 4 DSA Preboot 152 FCC Class A notice 230 diagnostic messages 155 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 253
5 power-on 5 rear 7 IBM director 16 system information 6 IBM Director system locator 6 updating 42 system-error 6 IBM Support Line 224 rear 7 important notices 2 system-locator installing rear 7 adapters 69 LEDs air baffle, center 65...
Page 254
Microsoft Windows 2003 configuration 35 power 142, 219 Red Hat Enterprise Linux configuration 29 serial port 143 SUSE SLES configuration 33 software 145 OSA SMBridge management utility program 40 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 255
problems (continued) removing (continued) undetermined 220 simple-swap backplate 96 USB port 146 simple-swap SATA hard disk drive 73 video 146 system board 110 product recycling and disposal 227 replacement parts 47 publications 1 resetting passwords 22 restore settings 21 riser-card assembly installing 67 location 67, 68 rack release latches 6...
Page 256
20, 120 system information 17 system reliability 58 system security 17 passwords 17 system specifications 3 system summary 17 system-locator rear 7 systems-management Ethernet connector 7 IBM System x3350 Type 4192 and 4193: Problem Determination and Service Guide...
Page 258
Part Number: 49Y0081 Printed in USA (1P) P/N: 49Y0081...