Configuring the Data Link Layer Protocol for E1, T1, and Serial Interfaces
Figure 14-44. PPP Configuration Window
1.
From the PPP Configuration window, enter a string of text up to 80
characters in the Description box if you want to record information about
the PPP interface. This description will be displayed in the running-config.
2.
Select the Enabled box to activate the interface.
3.
If you do not want the interface to use Weighted Fair Queuing (WFQ),
check the box to deselect it. For more information about WFQ, see
"Configuring WFQ" on page 16-59 in Chapter 16: Using the Web Browser
Interface for Advanced Configuration Tasks of the Advanced Manage-
ment and Configuration Guide.
4.
For most environments, you will accept the default MTU of 1500. If you
need to adjust the MTU, however, enter the new value in the MTU box.
5.
Verify that the PPP interface is bound to the correct physical interface.
6.
If you have not set a QoS Policy, None is displayed for its QoS policy. To
create a QoS policy, see "Configuring Quality of Service" on page 16-58 in
Chapter 16: Using the Web Browser Interface for Advanced Configura-
tion Tasks of the Advanced Management and Configuration Guide.
7.
To configure the IP address of the PPP peer, select the Default Peer IP
Address box, and enter the IP address in the boxes provided.
8.
To configure authentication, see "PPP Authentication" on page 14-65.