Enabling 802.1X Supplicant Status

To enable the router to function as a supplicant, complete the following steps:
1.
Move to the configuration mode context for the Ethernet interface that
you want to use to access the 802.1X-secured network.
ProCurve(config)# interface eth 0/1
ProCurve(config-eth 0/1)#
2.
Configure the supplicant username and password:
Syntax: port-auth supplicant username <username> password <password>
For example, you might enter:
ProCurve(config-eth 0/1)# port-auth supplicant username ProCurve password
ProCurve
The default username is username, and the default password is pass-
word.
3.
Enable the interface's supplicant functionality by entering the following:
ProCurve(config-eth 0/1)# port-auth supplicant