Warning: The 9160 G2 must be installed by qualified Psion Teklogix personnel.
2.1

Choosing The Right Location

Typically, Psion Teklogix conducts a site survey and then recommends the preferred loca-
tions for the 9160 G2s. These locations provide good radio coverage, minimize the distance
to the host computer or network controller, and meet the environmental requirements.
2.1.1

Environment

The 9160 G2 should be located in a well-ventilated area and should be protected from
extreme temperature fluctuations (i.e. direct heater output, shipping doors or direct sun-
light). If a protective cover is required, it must have enough ventilation to maintain regular
unit operation.
Refer to Chapter 27: "Specifications" for a more detailed description of environmental re-
quirements. Keep in mind that the long term stability of this equipment will be enhanced if
the environmental conditions are less severe than those listed in this manual.
The 9160 G2 should be situated away from the path of vehicles and free from water or dust
spray. The 9160 G2 should only be mounted in the upright position, as shown in Figure 2.1
on page 18. This orientation minimizes the risk of water entering the 9160 G2, should the
unit accidentally be sprayed.
The 9160 G2 is attached to a vertical surface using four fasteners on the rear plate (type of
fasteners are dependent on mounting surface). The top two holes in the rear plate are slots,
allowing the unit to be hung in position before the remaining bolts are installed, thus easing
installation. The bolts used for installation are SAE 1/4-20.
Psion Teklogix 9160 G2 Wireless Gateway User Manual

Chapter 2: Installation Requirements

Choosing The Right Location

17