Psion Teklogix 9160 G2 User Manual page 287

Wireless gateway
Hide thumbs Also See for 9160 G2:
Table of Contents

Advertisement

Chapter 23: Mini-Controller Configuration
3274 Emulation
The 9160 G2 reduces data transmitted to the mobile computers by using the mobile com-
puter's capability to store a page of data for each screen it displays. The 9160 G2 maintains
an image of each page stored at the mobile computer. After receiving an application screen,
the 9160 G2 tries to match the screen with a stored page. If a similar page is already in the
mobile computer's memory, the 9160 G2 instructs the mobile computer to redisplay its copy
of the page; only the necessary changes are sent from the controller. If no match is found, the
complete page is sent to the mobile computer over the radio link.
Note: There is a corresponding parameter on the mobile computer itself, and the actual
number of saved pages will be the smaller of the two values.
Transmit Line
When this feature is enabled, all modified data at the mobile computer is automatically
transmitted when the operator enters data into a transmit-upon-entry field.
The value in this textbox specifies the line on the screen which is designated the transmit
line. The last entry field above or on the transmit line on the screen will be identified as the
transmit-upon-entry field. If any entry fields exist on lines below the transmit line, no entry
field will be designated as the transmit-upon-entry field.
A value of 0 (zero) disables this feature. A value of 24 designates the last entry field on each
application screen as transmit-upon-entry.
AIAG
This parameter provides auto-locate and fill for input coming from bar code readers. When
bar code data is entered at a mobile computer, the mobile computer searches for "AIAG"
fields on the current page that can accept the bar code data. The data preloaded into the
"AIAG" field by the application program determines whether or not the bar code data is
accepted.
At the 9160 G2 mini-controller, a decimal value of an ASCII character from 0 to 255 is set
to match the "AIAG Field Identifier" set at the host. A value of 0 disables this feature.
The format of the preloaded data is as follows:
<mode> <AIAG prefix(data)>
The mode character used with the command allows for different operating modes to suit
various application operations. The automatic locate and fill operation applies only to data
received from a bar code reader. Descriptions of the modes and AIAG prefix are listed in
Table 23.1 on page 264. These modes are set at the host.
Psion Teklogix 9160 G2 Wireless Gateway User Manual
263

Advertisement

Table of Contents
loading

Related Products for Psion Teklogix 9160 G2

Table of Contents