Assigning Trunk/line data
Table 41 Combined line settings table (Continued)
Trunk types
Attribute
All
Distinct ring
Loop start analog
Auto privacy
Loop start digital
Ground start digital
DID
E&M
BRI
VoIP
Loop start analog
Trunk mode
Loop start digital
N0008589 3.3
Value
Description
None
Choose the distinctive ring pattern that you want to assign to
Pattern 2
the line. This allows you to provide selective service to calls
Pattern 3
with differing answer priorities.
Pattern 4
When more than one line with the distinct ring settings rings
at a telephone, the line with the highest priority will ring first.
Pattern 4 has the highest ring priority
Pattern 3 has second highest ring priority
Pattern 2 has third highest ring priority
None has the lowest ring priority.
By default, all telephones and lines are set to None
WARNING
If you assign a distinctive ring pattern to a line, and that distinctive ring pattern
has already been assigned to a telephone, all telephones with that ring pattern
will be reset to pattern 1.
If you assign a distinctive ring pattern to a telephone, and that distinctive ring
pattern has already been assigned to a line, all lines with that ring pattern will be
reset to None.
Refer to
"Defining user preferences" on page 428
assigning a distinctive ring pattern to a telephone.
You can also assign a distinctive ring pattern to a Hunt group. Refer to
"Identifying a Hunt group" on page
Y or N
Define whether one Business Communications Manager
user can select a line in use at another telephone to join an
existing call. Refer to
page 270
Note: This setting has no effect on VoIP lines.
Unspr
Define whether disconnect supervision, also referred to as
Supervised
loop supervision, releases an external line when an open
switch interval (OSI) is detected during a call on that line.
*Earth calling
You must set this to Supervised if a loop trunk has its Answer
*Loop guarded
mode set to Auto or if you enable Answer with DISA.
*Loop
Disconnect supervision is also required to conference two
unguarded
external callers. The line must be equipped with disconnect
supervision from the central office for the Supervised option
to work.
* These listing only appear for UK analog lines. Note that
Earth calling is only supported by a FEM connected to a
Norstar analog trunk module. The GATM does not support
Earth calling, even though the setting appears for the lines on
the module.
Tips: The duration of an open switch interval (OSI) before
Business Communications Manager disconnects a call is
programmed by the Disconnect timer setting. Refer to
"Configuring the trunk module to line type" on page
for information about
579.
"Turn Privacy on or off for a call" on
(FEATURE 83).
143.