CUTTING UNIT
Bedknife Backing Assembly
Removal
See Figures 8-26 through 8-28.
1. Park the mower safely. (See "Park Mower Safely" on
page 1-5.)
2. Remove cutting unit from mower. (See "Cutting Unit"
on page 8-20.)
2
NOTE
Steps 3 through 5 apply to both sides of the mower.
3. Loosen bedknife adjuster screws (1 and 2).
8
4. Remove the bedknife backing mounting screws (3).
8-22
1
Figure 8-26
3
Figure 8-27
4
5. Remove the bedknife backing assembly (4).
TN0893
TN0937
Figure 8-28
4262930-Rev A
TN0938