Carrier Weathermaster 48P030-100 Controls, Start-Up, Operation, Service, And Troubleshooting page 6

Single package large rooftop units with comfortlink version 9.x controls
Table of Contents

Advertisement

RUN
SERVICE
TEMPERATURES
STATUS
TEST
Auto View of
Service Test Mode
Run Status
(TEST)
Temperatures
(VIEW)
Software
Econ
Command
Run Status
Disable
Temperatures
(ECON)
(STOP)
Cooling
Soft Stop
Information
Request
(COOL)
(S.STP)
VFD
Supply Fan
Information
Request
(VFDS)
(FAN.F)
Mode
Test Independent
Trip Helper
Outputs
(TRIP)
(INDP)
CCN
Test Fans
Linkage
(FANS)
(LINK)
Calibrate Test
Compressor
Actuators
Run Hours
(ACT.C)
(HRS)
Test
Compressor
Humidimizer
Starts
(HMZR)
(STRT)
Test Cooling
Software
(COOL)
Version
Numbers
(VERS)
Test Heating
(HEAT)
Table 2 — Scrolling Marquee Menu Display Structure
PRESSURES
SETPOINTS
Air
Air Pressures
Occupied Heat
(AIR.P)
Setpoint
(AIR.T)
(OHSP)
Refrigerant
Refrigerant
Pressures
Occupied Cool
(REF.P)
Setpoint
(REF.T)
(OCSP)
Unoccupied
Heat Setpoint
(UHSP)
Unoccupied
Cool Setpoint
(UCSP)
Heat - Cool
Setpoint
(GAP)
VAV Occ
Cool On
(V.C.ON)
VAV Occ
Cool Off
(V.C.OF)
Supply Air
Setpoint
(SASP)
Supply Air
Setpoint Hi
(SA.HI)
Supply Air
Setpoint Lo
(SA.LO)
Heating Supply
Air Setpoint
(SA.HT)
Tempering
Purge SASP
(T.PRG)
Tempering in
Cool SASP
(T.CL)
Tempering in
Vent Occ SASP
(T.V.OC)
Tempering in
Vent Unocc.
SASP
(T.V.UN)
INPUTS
OUTPUTS
General Inputs
Fans
(GEN.I)
(FANS)
Compressor
Cooling
Feedback
(COOL)
(FD.BK)
Heating
Thermostat
(HEAT)
Inputs
(STAT)
Actuators
(ACTU)
Fire-Smoke
Modes
(FIRE)
General
Outputs
(GEN.O)
Relative
Humidity
(REL.H)
Air Quality
Sensors
(AIR.Q)
CFM Sensors
(CFM)
Reset Inputs
(RSET)
4-20 Milliamp
Inputs
(4-20)
6
TIME
CONFIGURATION
CLOCK
Unit Configuration
Time of Day
(UNIT)
(TIME)
Cooling Configuration
Month, Date,
(COOL)
Day and Year
(DATE)
Evap/Discharge
Temp. Reset
Local Time
(EDT.R)
Schedule
(SCH.L)
Heating Configuration
(HEAT)
Local
Holiday
Schedules
(HOL.L)
Supply Static
Press. Config.
(SP)
Daylight
Savings
Time
Economizer
(DAY.S)
Configuration
(ECON)
Building Press. Configs
(BP)
Cool/Heat
Setpt. Offsets
(D.L.V.T)
Demand Limit Config.
(DMD.L)
Indoor Air
Quality Cfg.
(IAQ)
Humidity
Configuration
(HUMD)
Dehumidification
Config.
(DEHU)
CCN Configuration
(CCN)
Alert Limit
Config.
(ALLM)
Sensor Trim
Config.
(TRIM)
Switch Logic
(SW.LG)
Display
Configuration
(DISP)
Supply Fan
VFD Config.
(S.VFD)
Exhaust Fan
VFD Config.
(E.VFD)
OPERATING
ALARMS
MODES
System
Currently
Mode
Active
(SYS.M)
Alarms
(CURR)
HVAC Mode
(HVAC)
Reset All
Current
Alarms
(R.CUR)
Control Type
(CTRL)
Alarm
History
Mode
(HIST)
Controlling
Unit
(MODE)