VFD OPERATION
The VFD keypad is shown in Fig. G-H. The functions of
ACH550/ACS320 SOFT KEYS (1 and 2) or ACH580 (
) change depending on what is displayed on the screen. The
function of SOFT KEY 1 matches the word in the lower left-hand
box on the display screen. The function of SOFT KEY 2 matches
the word in the lower right-hand box on the display screen. If the
box is empty, then the SOFT KEY does not have a function on
that specific screen. The UP and DOWN keys (ACH550/320) or
Arrow Keys (ACH580) are used to navigate through the menus.
The OFF key is used to turn off the VFD. The AUTO key is used
to change control of the drive to automatic control. The HAND
key is used to change control of the drive to local (hand held) con-
trol. The HELP button is used to access the help screens.
For the VFD to operate on the units covered by this document, the
drive must be set in AUTO mode. The word "AUTO" will appear
in the upper left-hand corner of the VFD display. Press the AUTO
button to set the drive in AUTO mode.
Display
Left Softkey
Status LED
Arrow Keys
Off
Auto
Fig. G — ACH580 VFD Keypad — Front
Clip
RJ-45
Connector
Fig. H — ACH580 VFD Keypad — Back
APPENDIX D — VFD INFORMATION (CONT)
and
Right Softkey
Help
Hand
USB Connector
Type Code
Label
Battery
Cover
229
START UP BY CHANGING PARAMETERS INDI-
VIDUALLY
Initial start-up is performed at the factory. To start up the VFD by
changing individual parameters, perform the following procedure:
1.
For
320/550,
select
For
580,
The Main menu will display.
2.
Use the UP or DOWN keys to highlight PARAMETERS on
the
display
For
320/550,
press
For 580, press
.
3.
Use the UP or DOWN keys to highlight the desired parame-
ter
For
320/550,
press
For 580, press
.
4.
Use the UP or DOWN keys to highlight the desired parame-
ter,
For
320/550,
press
For 580, press
.
5.
Use the UP or DOWN keys to change the value of the param-
eter, then save or cancel the change. Any modifications that
are not saved will not be changed.
a. To
save
For
320/550,
press
For 580, press
b. To
cancel
For 320/550, press CANCEL (SOFT KEY 1).
For 580, press
6.
Choose another parameter or return to parameter groups list :
For 320/550, press EXIT/BACK (SOFT KEY 1).
For 580, press
to go back.
7.
Continue until all the parameters have been configured, then:
For 320/550, press EXIT/BACK (SOFT KEY 1).
For 580, press
to return to the main menu.
NOTE: The current parameter value appears above the high-
lighted parameter. To view the default parameter value, press
the UP and DOWN keys simultaneously. To restore the default
factory settings, select the application macro "HVAC Default"
(ACH550/320 only).
VFD MODES
The VFD has several different modes for configuring, operating,
and diagnosing the VFD.
The modes are:
Standard Display mode — shows drive status information
and operates the drive
Parameters mode — edits parameter values individually
Start-up Assistant mode — guides start-up and configuration
Changed Parameters mode — shows all changed parameters
Drive Parameter Backup mode — stores or uploads the
parameters
Clock Set mode — sets the time and date for the drive
I/O Settings mode — checks and edits the I/O settings
ACH580 Standard Display Mode
Use the standard display mode to read information on the drive
status and operate the drive. To reach the standard display mode,
press BACK until the LCD display shows status information as
described below. See Fig. I.
The top line of the LCD display shows basic status information of
the drive. The HAND icon indicates that the drive control is local
from the control panel. The AUTO icon indicates that the drive is
in remote control mode, such as the basic I/O or field bus.
MENU
(SOFT
KEY
press
screen,
SEL
(SOFT
KEY
group,
SEL
(SOFT
KEY
EDIT
(SOFT
KEY
the
SAVE
(SOFT
KEY
to store the modified value.
the
to keep the previous value.
2).
.
then:
2).
then:
2).
then:
2).
change:
2).
change: