ITEM
OAT.L
OAT lo alert limit
OAT.H
OAT hi alert limit
R.RH.L
RARH low alert limit
R.RH.H
RARH high alert limit
O.RH.L
OARH low alert limit
O.RH.H
OARH high alert limit
SP.L
SP low alert limit
SP.H
SP high alert limit
BP.L
BP lo alert limit
BP.H
BP high alert limit
IAQ.H
IAQ high alert limit
TRIM
SENSOR TRIM CONFIG.
SAT.T
Air Temp Lvg SF Trim
RAT.T
RAT Trim
OAT.T
OAT Trim
SPT.T
SPT Trim
L.SW.T
Limit Switch Trim
CCT.T
Air Temp Lvg Evap Trim
DTA.1
A1 Discharge Temp Trim
SP.A.T
Suct.Press.Circ.A Trim
SP.B.T
Suct.Press.Circ.B Trim
DP.A.T
Dis.Press.Circ.A Trim
DP.B.T
Dis.Press.Circ.B Trim
SW.LG
SWITCH LOGIC: NO / NC
FTS.L
Filter Status Inpt-Clean
IGC.L
IGC Feedback - Off
RMI.L
RemSw Off-Unoc-Strt-NoOv
ENT.L
Enthalpy Input - Low
SFS.L
Fan Status Sw. - Off
DL1.L
Dmd.Lmt.Sw.1 - Off
DL2.L
Dmd.Lmt.Sw.2 - Off
IAQ.L
IAQ Disc.Input - Low
FSD.L
Fire Shutdown - Off
PRS.L
Pressurization Sw. - Off
EVC.L
Evacuation Sw. - Off
PRG.L
Smoke Purge Sw. - Off
DH.LG
Dehumidify Sw. - Off
DISP
DISPLAY CONFIGURATION
TEST
Test Display LEDs
METR
Metric Display
LANG
Language Selection
PAS.E
Password Enable
PASS
Service Password
S.VFD
SUPPLY FAN VFD CONFIG
N.VLT
VFD1 Nominal Motor Volts
N.AMP
VFD1 Nominal Motor Amps
N.FRQ
VFD1 Nominal Motor Freq
N.RPM
VFD1 Nominal Motor rpm
N.PWR
VFD1 Nominal Motor HPwr
M.DIR
VFD1 Motor Direction
ACCL
VFD1 Acceleration Time
DECL
VFD1 Deceleration Time
SW.FQ
VFD1 Switching Frequency
TYPE
VFD1 Type
E.VFD
EXHAUST FAN VFD CONFIG
N.VLT
VFD2 Nominal Motor Volts
N.AMP
VFD2 Nominal Motor Amps
N.FRQ
VFD2 Nominal Motor Freq
N.RPM
VFD2 Nominal Motor rpm
N.PWR
VFD2 Nominal Motor HPwr
M.DIR
VFD2 Motor Direction
ACCL
VFD2 Acceleration Time
DECL
VFD2 Deceleration Time
SW.FQ
VFD2 Switching Frequency
TYPE
VFD2 Type
NOTE(S):
a. Model number dependent.
APPENDIX A — LOCAL DISPLAY TABLES (CONT)
Table H — MODE — CONFIGURATION (cont)
EXPANSION
–40 to 245
–40 to 245
0 to 100
0 to 100
0 to 100
0 to 100
0 to 5
0 to 5
–0.25 to 0.25
–0.25 to 0.25
0 to 5000
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–50 to 50
–50 to 50
–50 to 50
–50 to 50
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
Open/Close
ON/OFF
ON/OFF
0 to 1 (multi-text strings)
ENABLE/DISABLE
0000 to 9999
0 to 999
0 to 999
10 to 500
50 to 30000
0 to 500
0=FWD, 1=REV
0 to 1800
0 to 1800
0=1kHz, 1=4kHz, 2=8kHz, 3=12kHz
0=LEN, 1=ANALOG
0 to 999
0 to 999
10 to 500
50 to 30000
0 to 500
0=FWD, 1=REV
0 to 1800
0 to 1800
0=1kHz, 1=4kHz, 2=8kHz, 3=12kHz
0=LEN, 1=ANALOG
RANGE
UNITS
dF
OATL
dF
OATH
%
RRHL
%
RRHH
%
ORHL
%
ORHH
"H2O
SPL
"H2O
SPH
"H2O
BPL
"H2O
BPH
IAQH
^F
SAT_TRIM
^F
RAT_TRIM
^F
OAT_TRIM
^F
SPT_TRIM
^F
LSW_TRIM
^F
CCT_TRIM
^F
DTA1TRIM
PSIG
SPA_TRIM
PSIG
SPB_TRIM
PSIG
DPA_TRIM
PSIG
DPB_TRIM
FLTSLOGC
GASFANLG
RMTINLOG
ENTHLOGC
SFSLOGIC
DMD_SW1L
DMD_SW2L
IAQINLOG
FSDLOGIC
PRESLOGC
EVACLOGC
PURGLOGC
DHDISCLG
TEST
DISPUNIT
LANGUAGE
PASS_EBL
PASSWORD
Volts
VFD1NVLT
Amps
VFD1NAMP
Hz
VFD1NFRQ
rpm
VFD1Nrpm
HP
VFD1NPWR
VFD1MDIR
sec
VFD1ACCL
sec
VFD1DECL
VFD1SWFQ
VFD1TYPE
Volts
VFD2NVLT
Amps
VFD2NAMP
Hz
VFD2NFRQ
rpm
VFD2Nrpm
H.P.
VFD2NPWR
VFD2MDIR
sec
VFD2ACCL
sec
VFD2DECL
VFD2SWFQ
VFD2TYPE
197
CCN POINT
DEFAULT
–40
98
150
98
0
98
100
98
0
98
100
99
0
99
2
99
–0.25
99
0.25
99
1200
99
0
99
0
99
0
99
0
99
0
99
0
99
0
99
0
99
0
100
0
100
0
100
Open
100
Open
100
Open
100, 103
Close
100
Open
100
Open
100
Open
100
Open
100
Open
100
Open
100
Open
100
Open
100
Open
100
Off
101
Off
101
0
101
Enable
101
1111
101
460
a
101
55.0
a
101
60
101
1750
101
40
101
a
0
101
30
101
30
101
2
101
0
101
460
102
a
28.7
a
102
60
102
1750
102
20
a
103
0
103
30
103
30
103
2
103
0
103