Carrier Weathermaster 48P030-100 Controls, Start-Up, Operation, Service, And Troubleshooting page 39

Single package large rooftop units with comfortlink version 9.x controls
Table of Contents

Advertisement

ITEM
TEST
Service Test Mode
STOP
Local Machine Disable
S.STP
Soft Stop Request
FAN.F
Supply Fan Request
INDP
TEST INDEPENDENT OUTPUTS
HUM.R
Humidifier Relay
ALRM
Remote Alarm/Aux Relay
FANS
TEST FANS
F.MOD
Fan Test Automatic?
E.POS
Econo Damper Command Pos
S.FAN
Supply Fan Relay
S.VFD
Supply Fan Commanded %
P.E.1
Power Exhaust Relay 1
E.VFD
Exhaust Fan Commanded %
P.E.2
Power Exhaust Relay 2
OV.A
Outdoor Fan VFD A Control Cmd %
OV.B
Outdoor Fan VFD B Control Cmd %
BP1.C
BP 1 Command Position
BP2.C
BP 2 Command Position
CDF.1
Condenser Fan Output 1
CDF.2
Condenser Fan Output 2
CDF.3
Condenser Fan Output 3
CDF.4
Condenser Fan Output 4
E.TST
ECONOMIZER AUTO-TEST
EC.TR
Run Economizer Auto-Test
Test Status & Timer
EC.DT
0=WAITING, 1=00:00:00
S.VFD
VFD1 Actual Speed %
TORQ
VFD1 Torque Moving Avg.
ECN.P
Economizer Act.Curr.Pos.
EC2.P
Economzr 2 Act.Curr.Pos.
Econ Auto-Test Result
0=NOT RUN, 1=RUNNING, 
ET.SR
2=PASSED, 3=FAILED
AC.T.C
CALIBRATE TEST-ACTUATORS
ECN.C
Economizer Act.Cmd.Pos.
EC.CL
Economizer Calibrate Cmd
ECN.A
Econ Act. Control Angle
EC2.C
Economzr 2 Act.Cmd.Pos.
E2.CL
Economzr 2 Calibrate Cmd
EC2.A
Econ2 Act.Control Angle
BP1.C
BP 1 Command Position
B1.CL
BP 1 Actuator Cal Cmd
BP1.A
BP Act.1 Control Angle
BP1.M
BP 1 Actuator Max Pos.
BP2.C
BP 2 Command Position
B2.CL
BP 2 Actuator Cal Cmd
BP2.A
BP Act.2 Control Angle
BP2.M
BP 2 Actuator Max Pos.
HTC.C
Ht.Coil Command Position
HT.CL
Heating Coil Act. Cal.Cmd
HTC.A
Heat Coil Act.Ctl.Angle
HMD.C
Humidifier Command Pos.
HM.CL
Humidifier Act. Cal.Cmd
HMD.A
Humidifier Act.Ctrl.Ang.
SRCH
SEARCH FOR SERIAL NUMBER
ACTV
Belimo Serial Num Search No/Yes
ECN.1
Economizer 1 Search
ECN.2
Economizer 2 Search
HUMD
Humidifier Valve Search
HT.CL
Heat Coil Valve Search
BP.1
Building Press 1 Search
BP.2
Building Press 2 Search
HMZR
TEST HUMIDIMIZER
RHV
Humidimizer 3-Way Valve
C.EXV
Condenser EXV Position
B.EXV
Bypass EXV Position
C.CAL
Condenser EXV Calibrate
B.CAL
Bypass EXV Calibrate
Table 30 — Service Test
EXPANSION
RANGE
UNITS
ON/OFF
YES/NO
YES/NO
YES/NO
ON/OFF
ON/OFF
YES/NO
%
ON/OFF
0 to 100
%
ON/OFF
0 to 100
%
ON/OFF
0 to 100
%
0 to 100
%
0 to 100
%
0 to 100
%
ON/OFF
ON/OFF
ON/OFF
ON/OFF
YES/NO
0 to 100
%
YES/NO
read only
0 to 100
%
YES/NO
read only
0 to 100
%
YES/NO
read only
0 to 100
%
0 to 100
%
YES/NO
read only
0 to 100
%
0 to 100
%
YES/NO
read only
0 to 100
%
YES/NO
read only
ON/OFF
0 to 100
%
0 to 100
%
ON/OFF
ON/OFF
39
CCN POINT
WRITE STATUS
MAN_CTRL
UNITSTOP
config
SOFTSTOP
forcible
SFANFORC
forcible
HUMR_TST
ALRM_TST
FANAUTO
ECONFANS
SFAN_TST
SFVFDTST
PE1_TST
EFVFDTST
PE2_TST
OV_A_TST
OV_B_TST
BLDPTST1
BLDPTST2
CND1_TST
CND2_TST
CND3_TST
CND4_TST
AC_EC
DD_TEXT
VFD1_SPD
VFD1TMAV
ECONOPOS
ECON2POS
AC_EC_ST
ECON1TST
ECONOCAL
ECONCANG
ECON2TST
ECON2CAL
ECN2CANG
BLDG1TST
BLDG1CAL
BP1_CANG
BP1SETMX
BLDG2TST
BLDG2CAL
BP2_CANG
BP2SETMX
HTCLACTC
HCOILCAL
HTCLCANG
HUMD_TST
HUMIDCAL
HUMDCANG
BELSERCH
EC1SERCH
EC2SERCH
HUMSERCH
HTCSERCH
BP1SERCH
BP2SERCH
RHVH_TST
CEXVHTST
BEXVHTST
CEXV_CAL
BEXV_CAL